Functions and control
7.1.5
:
Protection function
7.1.5.1
:
TTC high temperature-preventing protection
Once the machine is started, it can run TTC overheating protection of air-blowing, but air-blowing sensor
malfunction must alarm after 4 minutes during which the compressor is started (during the course of
self-detection, there’s no such limitation)
Sensor detection methods: 100 times (one cycle of procedure run is one time, and about 5ms, detection
method for each time: continuously sampling for 8 times, then order them and take the mean value of the
middle 2 values), take the mean value.
TTC
(℃)
Abnormal stop
115
Decreasing the frequency rapidly
(
1HZ/second
)
110
Decreasing the frequency slowly (1HZ/10seconds)
105
The frequency doesn’t change.
98
Increasing the frequency (1HZ/10second)
95
Increasing the frequency
(
1HZ/1second
)
TTC>=115
℃
lasts for 20 seconds. Overheating protection of air-blowing, alarm malfunction to the indoor,
others don’t last.
7.1.5.2
:
TC high temperature-preventing control of the indoor heating unit
Tpg_indoor is the highest value of the effective indoor unit (start it and it is in accord with the running state).
The indoor heat exchanger sensor tests the temperature of the indoor heat exchanger. If the temperature is
higher than 48
℃
, decrease the rotate speed of the compressor and do the high temperature-preventing
protection of the indoor heat exchanger; if the temperature of the indoor heat exchanger is lower than 45
℃
,
recover to the normal control.
TC The compressor stops
Fgh_t1
-
2 Fgh_t1 63
℃
N Decreasing the frequency rapidly Fgh_t2 59
℃
Fgh_t2
-
2 P Decreasing the frequency slowly
Fgh_t3 55
℃
Fgh_t3
-
2 Q Prohibiting increasing the frequency
Fgh_t4 51
℃
Fgh_t4—2 R Increasing slowly Fgh_t5 47
℃
Fgh_t5—2
Normal
N
:
Decreasing at the speed of 1HZ/1second
P
:
Decreasing at the speed of 1Hz/10seconds
Q
:
Continue to keep the last-time instruction cycle
R
:
Increasing at the speed of 1Hz/10seconds
Domestic air conditioner
18
Содержание 1U35QA1ERA
Страница 11: ...Pinping diagrams Domestic air conditioner 4 Pinping diagrams 9 EXV EXV ...
Страница 12: ...Operation range Domestic air conditioner 5 Operation range 10 10 0 20 16 32 10 20 15 ...
Страница 15: ...Connector Wiring Diagram Domestic Air Conditioner 13 PCB 2 12K CN2 CN3 CN4 CN5 CN6 CN7 CN11 CN10 CN1 CN8 CN9 ...
Страница 16: ...Functions and control Domestic air conditioner Wiring diagrams 14 OUTDOOR WIRING DIAGRAM 0010581667 80 ...
Страница 57: ...Circuit diagrams Domestic air conditioner 13 2 Module board Circuit Diagram 55 ...