background image

Step 4: Install RO Faucet

You will need a sink top hole between 11/2” and 15/8” in diameter. If drilling a new hole, ensure faucet body 

will mount flat against surface and that there is sufficient tubing between faucet body and system manifold. 

NOTE: Drilling holes into solid surfaces or surfaces made of stone should only be performed by a qualified and 

certified installer.

1.  Attach remaining 3/8” white tubing to stem on faucet body by wetting tubing end and 

inserting into faucet stem fitting approximately 5/8” until it stops. Gently tug on the 
tubing to ensure it is firmly seated in fitting. 

2.  NOTE: Do not connect 3/8” white tubing from tank to faucet.

3.  Mount faucet base by pushing toggle bolts through the sink hole until faucet base is 

flush with countertop. Position toggle bolts under sink surface being certain faucet 
stem will not be obstructed. Loosely fasten faucet base to countertop by tightening 
toggle bolts, alternating between left and right sides to evenly tighten. Leave loose to 
adjust faucet body as desired.

4.  Route the 3 tubes attached to faucet body through the faucet base and through hole 

in sink until approximately 12” of tubing remains above sink. 

5.  Turn ¼ clockwise and holding faucet base firmly, mount faucet body to faucet base. 

Adjust faucet body handle to desired location. 

6.  To tighten faucet, hold base firmly to keep it from moving while turning faucet body 

1/4 turn counterclockwise. Tighten toggle bolts evenly, making sure not to over tighten.

7.  Mount faucet body to faucet base; turn ¼ turn clockwise until it locks.

8.   Attach  faucet 

spout to faucet 
body by screwing 
spout nut to body.

1

5

2

6

3

7

4

Содержание AquaH20 HF-RO

Страница 1: ...AquaH20 Drinking Water System Owner s Manual MODEL HF RO...

Страница 2: ...out G RO Faucet Body Stem stem not shown H Water Storage Tank I Eye Dropper J Tank Connector K Teflon Tape L Drain Connector M Nuts Bolts N Foam Seal O O Ring Faucet Base P Toggle Bolts Q Flow Restric...

Страница 3: ...o ensure adequate space and proper positioning 3 8 white tubing will be used to connect manifold to tank and from faucet stem to remineralizer Measure out 3 8 white tubing from the top of the tank to...

Страница 4: ...e tube in place tighten the compression nut to compress the plastic sleeve and create a seal NOTE Use a wrench to ensure complete seal Avoid over tightening 5 Do not connect the other end at this time...

Страница 5: ...e tubing through the nut collar and sleeve into the connector B Unscrew the compression nut from the tank connector to ensure that the tubing is connected all the way through the collar and sleeve C S...

Страница 6: ...k hole until faucet base is flush with countertop Position toggle bolts under sink surface being certain faucet stem will not be obstructed Loosely fasten faucet base to countertop by tightening toggl...

Страница 7: ...ocation 2 Remove protective cover from back of foam seal 3 Knock center hole out align holes and attach to front plate of drain connector 4 Allowing room for drilling position the drain connector on s...

Страница 8: ...ing in order to prevent crimping kinks loops or folds TUBING DONT S DO NOT cut tubing too short Always double check measurements before cutting DO NOT bend or crimp or kink tubing DO NOT discard exces...

Страница 9: ...lled in step 4 from the faucet into the remineralizer port labeled OUTLET IV Manifold to Tank 3 8 white tubing already attached to tank 1 Take the white tubing leading from the storage tank and insert...

Страница 10: ...ttach red carbon sump to the 1st stage position on the inlet side of the system manifold Make sure all con nection points are aligned and push the top of the sump up and into the system manifold Turn...

Страница 11: ...System 2 To purge air from the plumbing system open kitchen faucet Close faucet when water runs smooth 3 Confirm RO faucet is closed 4 Within approximately 2 hours pressure will start to build in the...

Страница 12: ...conditions on the above are 250 ppm TDS and a 30 6 recovery rate Production rate and TDS reduction figures are for a new Membrane that has been rinsed for 24 hours The production rate of a new Membran...

Страница 13: ...rapidly convert trivalent arsenic to pentavalent arsenic Other water treatment chemicals such as ozone and potassium permanganate will also change trivalent arsenic to pentavalent arsenic A combined c...

Страница 14: ...igher than 8 0 membrane life may be as short as 12 months If pH is under 7 5 membrane life may last up to 36 months When output water quality and production rate decrease it is time to replace the fil...

Страница 15: ...It is recommended the restrictor assembly be periodically inspected to be sure it is clean and unrestricted If service is required on the drain flow assembly disassemble and reassemble as outlined in...

Страница 16: ...ternational against NSF ANSI Standards 42 and 53 in model HF RO for the reduction claims specified on the Performance Data Sheet as verified and substantiated by test data and at nsf org The HF RO sys...