background image

Step 3: Install Water Storage Tank

1.  On the nipple on top of the tank, apply Teflon

®

 tape 4 or 5 times clockwise around in 

the same direction as the threads.

2.  Hand tighten the tank connector onto the tank nipple until secure. 

NOTE: Do not cross thread or over tighten.

3.  Using mount stand, place tank near the system 

manifold. Measure 3/8" white tubing to the outlet side 
of the system manifold and ensure you have enough 
tubing to connect tank and system manifold as well as 
enough left to attach faucet stem and remineralizer. 
Cut 3/8" white tubing.

4.  Install the 3/8" white tubing to the tank:

A.  Push the tubing through the nut, collar and 

sleeve into the connector.

B.   Unscrew the compression nut from the tank 

connector to ensure that the tubing is connected 
all the way through the collar and sleeve.

C.   Slide the nut to the threads and tighten with a 

wrench. Avoid over tightening.

3.  Drill two pilot holes for mounting 

brackets using 1/8" drill bit for the 
system manifold.  

NOTE: Use caution 

not to drill into anything beyond the 

cabinet wall.

4.  Insert mounting screws into the wall 

leaving approximately 3/8" of each 
screw exposed.

5.  Remove first and third filter sumps 

from manifold by turning each sump to the left and pulling down before hanging mani-
fold on wall. Mount manifold on wall and screw in. Be careful not to over tighten.

6.  Screw in remineralizer holder onto wall.

OptimH2O™

OptimH2O™

OptimH2O™

Содержание AquaH20 HF-RO

Страница 1: ...AquaH20 Drinking Water System Owner s Manual MODEL HF RO...

Страница 2: ...out G RO Faucet Body Stem stem not shown H Water Storage Tank I Eye Dropper J Tank Connector K Teflon Tape L Drain Connector M Nuts Bolts N Foam Seal O O Ring Faucet Base P Toggle Bolts Q Flow Restric...

Страница 3: ...o ensure adequate space and proper positioning 3 8 white tubing will be used to connect manifold to tank and from faucet stem to remineralizer Measure out 3 8 white tubing from the top of the tank to...

Страница 4: ...e tube in place tighten the compression nut to compress the plastic sleeve and create a seal NOTE Use a wrench to ensure complete seal Avoid over tightening 5 Do not connect the other end at this time...

Страница 5: ...e tubing through the nut collar and sleeve into the connector B Unscrew the compression nut from the tank connector to ensure that the tubing is connected all the way through the collar and sleeve C S...

Страница 6: ...k hole until faucet base is flush with countertop Position toggle bolts under sink surface being certain faucet stem will not be obstructed Loosely fasten faucet base to countertop by tightening toggl...

Страница 7: ...ocation 2 Remove protective cover from back of foam seal 3 Knock center hole out align holes and attach to front plate of drain connector 4 Allowing room for drilling position the drain connector on s...

Страница 8: ...ing in order to prevent crimping kinks loops or folds TUBING DONT S DO NOT cut tubing too short Always double check measurements before cutting DO NOT bend or crimp or kink tubing DO NOT discard exces...

Страница 9: ...lled in step 4 from the faucet into the remineralizer port labeled OUTLET IV Manifold to Tank 3 8 white tubing already attached to tank 1 Take the white tubing leading from the storage tank and insert...

Страница 10: ...ttach red carbon sump to the 1st stage position on the inlet side of the system manifold Make sure all con nection points are aligned and push the top of the sump up and into the system manifold Turn...

Страница 11: ...System 2 To purge air from the plumbing system open kitchen faucet Close faucet when water runs smooth 3 Confirm RO faucet is closed 4 Within approximately 2 hours pressure will start to build in the...

Страница 12: ...conditions on the above are 250 ppm TDS and a 30 6 recovery rate Production rate and TDS reduction figures are for a new Membrane that has been rinsed for 24 hours The production rate of a new Membran...

Страница 13: ...rapidly convert trivalent arsenic to pentavalent arsenic Other water treatment chemicals such as ozone and potassium permanganate will also change trivalent arsenic to pentavalent arsenic A combined c...

Страница 14: ...igher than 8 0 membrane life may be as short as 12 months If pH is under 7 5 membrane life may last up to 36 months When output water quality and production rate decrease it is time to replace the fil...

Страница 15: ...It is recommended the restrictor assembly be periodically inspected to be sure it is clean and unrestricted If service is required on the drain flow assembly disassemble and reassemble as outlined in...

Страница 16: ...ternational against NSF ANSI Standards 42 and 53 in model HF RO for the reduction claims specified on the Performance Data Sheet as verified and substantiated by test data and at nsf org The HF RO sys...