WaterMax ST Series Owner’s Manual
5/11/2018
43
Water Conditioner Specifications, Cont.
ST Series
2AMQ
1
2APQ
1
2AKQ
2AJQ
3
Max Compensated Hardness–gpg (g/L)
90 (1.5)
90 (1.5)
90 (1.5)
60 (1.0)
Iron (ppm)
5
ferrous-clear water
Maximum ferrous iron reduction
6
12
5
2-12
5,7
15
5
Minimum pH–standard units
7
7
7
6.3
Tannin–ppm
0
0
0
0
Sulfur–ppm-SulfurStat
0
0-5
7
0
0
Maximum Chlorine–ppm
0
0
0
0
Filtration-nominal rating–microns
20
20
20
20
Media Amount Compartment #1
8
–lb (kg)
Empty
Empty
Empty
Empty
Media Amount Compartment #2
8
–cu. ft. (L)
6 lb
(2.7 kg)
27 lb
(122.2 kg)
0.4 (11.3)
0.4 (11.3)
Media Amount Compartment #3 Fine Mesh
Cation Resin–cu. ft. (L)
1.06 (30)
1.06 (30)
1.06 (30)
1.06 (30)
Backwash Rate @ min. water pressure maximum
flow to drain–gpm (L/min)
5
9
(18.9)
Empty
9,10
7
9
(26.5)
7
9
(26.5)
Brine Line Flow Control Refill–gpm (L/min)
0.5 (1.9)
0.5 (1.9)
0.5 (1.9)
0.5 (1.9)
Water Pressure–min–max psi (bar)
20–120
(1.4–8.3)
30–120
(2.1–8.3)
30–120
(2.1–8.3)
30–120
(2.1–8.3)
Flow Rate @ 15 psi (1.0 bar) drop-as tested by
Hague–gpm (L/min)
11
12.2 (46.2)
12.7 (48.1)
10.6 (40.1)
12.5 (47.3)
Pressure Drop in psi (bar) @ Service Flow Rate
of 8 gpm (30.3 L/min)
7.8 (0.5)
6.0 (0.4)
10 (0.7)
11 (0.8)
#1 Setting–Salt lb/grains (kg/grams) removed
1.1/5,700
(0.5/369)
NA
NA
NA
#2 Setting—Salt lb/grains (kg/grams) removed
2.7/12,000
(1.2/778)
NA
NA
2.7/11,900
(1.2/771)
#3 Setting—Salt lb/grains (kg/grams) removed
6.2/23,400
(2.8/1,520)
6.2/24,600
(2.8/1,594)
6.2/23,100
(2.8/1,500)
6.2/23,100
(2.8/1,500)
#4 Setting—Salt lb/grains (kg/grams) removed
9.3/30,600
(4.2/1,980)
9.3/32,100
(4.2/2,080)
9.3/30,300
(4.2/1,960)
9.3/30,300
(4.2/1,960)
#1 Salt Setting–Total length of reg. Min/gal (L)
25/31
(25/117)
NA
NA
NA
#2 Salt Setting–Total length of reg. Min/gal (L)
28/32
(28/121)
NA
NA
34/70
(34/265)
#3 Salt Setting–Total length of reg. Min/gal (L)
31/35
(31/132)
37/78
(37/295)
37/78
(37/295)
37/78
(37/295)
#4 Salt Setting–Total length of reg. Min/gal (L)
36/37
(36/140)
41/80
(41/303)
41/80
(41/303)
41/80
(41/303)
Shipping weight–lb (kg)
140 (64)
167 (76)
160 (73)
180 (82)
Bacteriostatic-KDF
®
Process Media*
Yes
Yes
Yes
Yes
For All Models:
Use clean white pellet, cube-style, or solar salt.
Drain Line (Minimum I.D.) 1/2-inch (1.3 cm)
Height–inches (cm) 38–1/4 (97)
Salt storage capacity–lb (kg) 200 (90)
Electrical rating: 115V, 60 cycle
Valve Inlet/Outlet–1 inch
Water Temperature (Min-Max) 40°–120°F (4°–49°C)
Floor Space–inches (cm) 15 x 30 (38 x 76)
Brine & Rinse total–gpm (L/min) 0.75 (2.5)
Brine Draw–gpm (L/min) 0.25 (0.9)
Rinse–gpm (L/min) 0.5 (1.5)
Iron reduction to 0.3 ppm or less (Not certified by WQA.)
*Listed with the U.S. EPA as a Bacteriostatic Device U.S.
EPA # 54369-OH-001. Not certified by WQA.
1
Models 3MAQ, 3BAQ, 3BEQ, 3MXQ, 2AMQ and 2APQ are certified by WQA for barium and radium reduction as
verified and substantiated by test data. All other models are not certified by WQA and make no health claims.
2
Municipally supplied chlorinated water only.
3
Calcite will add additional hardness to water before softening.
4
Any hardness over 10 gpg (0.17 grams/liter) will increase the chance of calcium carbonate precipitation. As the
hardness increases so does the chance of this precipitation. Must use citric acid to regenerate along with salt.
5
Regeneration every 96 hours is required when iron is present in the raw water supply unless noted otherwise.
Use Salt Setting #3 or #4.
6
Iron reduction claims limited to 5 ppm in the state of Wisconsin.
7
Must have a minimum of 2 ppm iron and a minimum of 200 ppm TDS.
8
When adding media in the field, check for proper settings. (See Water Conditioner Specifications, above.)
9
Rate of flow must be verified at the end of 1/2-inch I.D. drain line.
10
This model has no backwash flow control button or retainer. Must have a minimum of 7 gpm @ 30 psi
(26.5 L/min @ 2.1 bar) available for proper backwash.
11
For the purposes of plumbing appliance sizing, only the rated service flow rate and corresponding pressure loss
may be used. Prolonged operation of a water softener at flow rates exceeding the tested service flow rate of 8 gpm
(30.3 L/min) may compromise performance.
Reduction capabilities for specific contaminants verified by test data.
Name of Substance
USEPA Max.
Contaminant Level
pH
Flow Rate
Pressure
Barium
2.0 mg/L
7.5 ± 0.5
10.0 gpm (37.9 L/min)
35 ± 5 psig (2.4 ± 0.3 bar)
Radium 226/228
5 pCi/L
7.5 ± 0.5
10.0 gpm (37.9 L/min)
35 ± 5 psig (2.4 ± 0.3 bar)
Содержание WaterMax 1AAN
Страница 1: ...WATER CONDITIONING APPLIANCE ST SERIES OWNER S MANUAL AND INSTALLATION GUIDE VERSION 1 1...
Страница 45: ...WaterMax ST Series Owner s Manual 5 11 2018 45 Certificates...
Страница 46: ...WaterMax ST Series Owner s Manual 5 11 2018 46 Certificates Cont...
Страница 47: ...WaterMax ST Series Owner s Manual 5 11 2018 47 Notes...