Model 410
Owner’s Manual
6/24/2014
21
Service Settings, Cont.
Operating Modes
The appliance has three operating modes: Timer mode, Meter Delayed mode, and Demand Immediate mode.
All three modes are equipped with Capacity Guard
®
, which ensures that a supply of conditioned water will be
available even with excessive water usage.
Mode 1
—Timer Mode
When the appliance is in Timer mode, it will regenerate based on the frequency that is set, for example every
two days or up to every 12 days. The time of regeneration can be set.
Mode 2
—Meter Delayed Mode
When the appliance is in Meter Delayed mode, it will regenerate based on the actual water usage and the total
capacity of the appliance. The time that the regeneration takes place can be set, for example 2:00 a.m. Should
the total capacity be depleted before the set regeneration time, a forced regeneration will occur.
Mode 3
—Demand Immediate Mode
When the appliance is in Demand Immediate mode, it will regenerate based on water usage alone.
Regeneration will occur when the capacity limit is reached.
72
–96 Hour Regeneration
If this value is set to Yes, the appliance will be forced to regenerate every 72–96 hours unless a regeneration
based on water usage occurs within the time interval. The value should always be set to Yes if iron is present in
the water.
Mode 1 (Timer Mode) and Mode 2 (Meter Delayed Mode) Setting Chart
This section provides guidance for using different service settings to achieve the desired capacity.
410
Mode 1 and 2
Yes
Regeneration Frequency
As required
96 hour regeneration (if iron present—yes)
1
—
#1 Salt Setting
Backwash 1 (minutes)
0.0
Brine/Rinse (minutes)
9
Backwash 2 (minutes)
2
Capacity-grains (grams) @ salt-lb (kg)
5,200 @ 1 (365 @ 0.5)
#2 Salt Setting
Backwash 1 (minutes)
0.0
Brine/Rinse (minutes)
12
Backwash 2 (minutes)
2
Capacity-grains (grams) @ salt-lb (kg)
8,300 @ 2 (540 @ 0.9)
#3 Salt Setting
Backwash 1 (minutes)
0.0
Brine/Rinse (minutes)
15
Backwash 2 (minutes)
2
Capacity-grains (grams) @ salt-lb (kg)
10,400 @ 3 (670 @ 1.4)
1
If iron is present in water supply, use salt setting #3.
Содержание Maximizer 410
Страница 35: ...Notes...