Service Settings
To program Service settings on the controller, press and hold the P and S buttons while “Service Settings” is
displayed until “Set Language” is displayed. Programming Service Settings is similar to programming Customer
Settings (see
Customer Settings
for programming details). The values that can be set are listed below. The
values in the table are factory default settings only.
Note:
This section is recommended for qualified service personnel only. The Service Settings must be set
before the Customer Settings.
Display
Meaning
Possible Values
Comments
Set Language Eng
Set the language of the
display
ENG=English, FRA=French,
ESP=Spanish, IT=Itailan,
Deutsch=German,
Units Eng (Units MET)
Units of measure
ENG=English (Gallons)
MET=Metric (Liters)
History?
No
Activates “History” file
No to skip History file
Yes to view/edit History file
The History file is used to record
initial values for later reference
H-Soft. V. #X.XX
Displays software
version
Cannot be set
Displays only when History is set
to Yes. Only an authorized
service technician should set and
save values.
H-Date
ddmmyy
Install Date (DDMMYY) 000000 to 999999
H-# People
04
Record number of
people when installed
00 to 99
H-Hard. Gr.
(H-Hard. mg/L)
018
(0300)
Record reading at time
of original installation
001-999
(0001-9999)
H-Iron ppm
(H-Iron mg/L)
00
00-99
H-Mang. ppm
(H-Mang. mg/L)
00
00-99
H-Sulfur ppm
(H-Sulfur mg/L)
000
000-999
H-pH
00.0
00.0-99.9
H-Iron Bact.
No
No or Yes
H-Total Regen
00000
Lifetime total of
regenerations
Cannot be reset
00000-99999
H-Tot. G
(H-Tot. L)
00000000 Lifetime total of water
passed through
appliance
Cannot be reset
00000000-99999999
H-Model #
M410
Model number
Cannot be set
H-Save Hist.
No
Saves history values
No or Yes
Mode
3
Operating
(Regeneration) Mode
Timer Mode (Mode 1)
Demand Delayed Mode
(Mode 2)
Demand Immediate Mode
(Mode 3)
See
Operating Modes