background image

11

IIn

nsstta

alllla

attiio

on

n  S

Stte

ep

pss  a

an

nd

d  S

Stta

arrtt--U

Up

p  P

Prro

oc

ce

ed

du

urre

ess

F

Fiillll  tth

he

e  B

Brriin

ne

e  T

Ta

an

nk

k  W

Wiitth

h  S

Sa

alltt

A. If the grid plate is not sitting on its supports at the 

bottom of the brine tank, carefully reposition it.

B. Fill the brine tank with salt. (See Figure 17.) Use clean, 

white pellet, solar, cube-type, block, or brick salt. Do not 
mix different types of salt.

Note

: Always keep the salt level above the water level. For 

convenience, completely fill the brine tank when refilling 
with salt.

C. Close the salt port lid.

CAUTION

: Use of potassium chloride when iron and/or 

manganese is present in the raw water supply is not 
recommended.

C

Co

om

mp

plle

ette

e  tth

he

e  IIn

nsstta

alllla

attiio

on

n

A. Open the inlet valve and turn on the electricity to the 

water heater. For gas water heaters, return the gas cock to “ON.”

B. Ensure that the bypass is left in the “service” position and the valve cover is on the appliance.

(See Figure 11 or 12.)

Figure 17: Fill Brine Tank With Salt

STEP 13

STEP 14

Содержание Maximizer 400

Страница 1: ...Installation and Service Manual Maximizer 400 4343 S Hamilton Rd Groveport OH 43125 Version 1 0 400...

Страница 2: ...s Cabinet and Cover 20 Assembly and Parts Cabinet and Assemblies 21 Assembly and Parts 3 4 I O Adapter 22 Assembly and Parts 1 I O Adapter 23 Assembly and Parts Bypass 24 Assembly and Parts Drive End...

Страница 3: ...and your appliance Keep it handy for a reference guide and service log Warning This appliance must be applied to potable water only Note Manufacturer reserves the right to make specification and produ...

Страница 4: ...disinfect your appliance add 1 5 fluid ounces 0 04 litres of chlorine bleach solution to the brine cabinet The brine cabinet should have water in it to carry the solution into the appliance Start a ma...

Страница 5: ...etting number If total hardness exceeds 35 grains 600 ppm of hardness do not install this unit and contact your water treatment specialist Water Pressure Not less than 20 psi nor greater than 120 psi...

Страница 6: ...120 F 49 C See Specifications 3 Do not allow soldering torch heat to be transferred to valve components or plastic parts 4 Do not over tighten the plastic fittings 5 Do not plumb the appliance agains...

Страница 7: ...re store or install three way bypass plumbing simi lar to Figure 3 I In ns st ta al ll la at ti io on n S St te ep ps s a an nd d S St ta ar rt t U Up p P Pr ro oc ce ed du ur re es s Figure 1 Applian...

Страница 8: ...o basement slab crawl space under counter and outside installations G For most installations install the appliance after the pressure tank and any water filter appliance or water meter and before the...

Страница 9: ...bly for 3 4 inch copper plumbing or 3 4 inch CTS CPVC plastic tubing Ensure that the three components 1 collar 2 metal retaining ring and 3 nylon sleeve are correctly installed in sequence on the pipe...

Страница 10: ...table waste receptor Maintain a minimum 2 inch 50 mm air gap between the drain line and the flood level rim of the waste receptor to prevent back siphoning This drain line should make the shortest run...

Страница 11: ...faucet and recheck for leaks C Co on nn ne ec ct t t th he e C Co on nt tr ro ol ll le er r A Connect the transformer power cord to the back of the controller See Figure 13 Do not plug the transforme...

Страница 12: ...to o t th he e B Br ri in ne e T Ta an nk k A Remove any packaging or installation materials Do NOT remove the grid plate B Add 1 5 gallons 5 7 litres of water to the brine cabinet C Ensure that the...

Страница 13: ...of salt Note Always keep the salt level above the water level For convenience completely fill the brine tank when refilling with salt C Close the salt port lid CAUTION Use of potassium chloride when...

Страница 14: ...flat blade screwdriver in the slot provided and turning clockwise to open Total movement of the blending valve from full closed to full open is 1 4 revolution Precise setting of the blending valve wil...

Страница 15: ...st ti ic c P PV VC C C CP PV VC C P Pi ip pe e J Jo oi in ni in ng g P Pr ro oc ce ed du ur re es s To ensure reliable joint integrity when using solvent cement for PVC CPVC plumbing follow these reco...

Страница 16: ...nsert the pipe into the fitting socket and give a one quarter turn of the pipe or fitting while pushing toward the fitting stop This action will evenly distribute the cement Do NOT continue to rotate...

Страница 17: ...n be used in two ways 1 The R button can be used to put the appliance into an immediate regeneration a Press and hold the R button for about five seconds until the display changes to Going to 1 b The...

Страница 18: ...S button to move the cursor one digit to the right of the parameter to be changed 2 When the cursor is at the extreme right position press the S button again to reset the cursor to the extreme left po...

Страница 19: ...g water 00 to 99 This value is used to calculate a compensated hardness automatically Salt Sodium Material filling the brine tank Salt Sodium Salt Potassium See SALT WARNING that follows Comp Hard 000...

Страница 20: ...on the frequency that is set for example every two days or up to every 12 days The time of regeneration can be set Mode 2 Demand Delayed Mode When the appliance is in the Patented Savematic demand de...

Страница 21: ...time that is set Usually you want to set a regeneration time when water will not be used The cursor will be under the second hours digit If the regeneration time displayed is correct press P To Change...

Страница 22: ...ansformer 220V 1 C0916 Japan Transformer 100V 1 3 56022 Computer Control Assembly 1 4 56004 Cabinet 1 5 56006 Support Panel 1 C Ca ab bi in ne et t a an nd d C Co ov ve er r A As ss se em mb bl li ie...

Страница 23: ...1 93809 Screw 2 2 93870 Screw 4 3 90614 3 0 Drain end cap 1 4 93808 O Ring 2 5 V185 Drain fitting 1 2 12 7 mm 1 6 93842 Drain hose 8 2 4 m 1 7 93838 O Ring 2 8 54512 Bypass assembly 1 9 C0700A Cabinet...

Страница 24: ...lv ve e S St ta an nd da ar rd d PART DESCRIPTION QUANTITY 1 93521 3 4 I O Assembly 1 2 90802 Screw 3 3 90252 Blending Dial Cap 1 4 90222 Blending Dial 1 5 90827 O Ring 1 6 90232 Turbine Sensor Cap 1...

Страница 25: ...ve e O Op pt ti io on na al l Figure 25 1 I O Adapter Assembly with Blending Valve PART DESCRIPTION QUANTITY 1 93252 1 I O Adapter Assembly 1 2 90802 Screw 3 3 90252 Blending Dial Cap 1 4 90222 Blendi...

Страница 26: ...ti io on na al l PART DESCRIPTION QUANTITY 1 93521 3 4 I O Assembly 1 2 93858 Turbine Sensor Assembly 1 3 90232 Turbine Sensor Cap 1 4 90809 Sensor Cap Screw 1 5 54320 Plastic Turbine Axle 1 6 90522 T...

Страница 27: ...e Gear 1 5 90809 Screw 2 6 93219 Piston Slide Cam Cover 1 7 93217 Piston Slide Cam 1 8 93583 Drive End Cap 1 9 93216 Piston Slide 1 10 90818 Screw 2 11 93601 Brine Valve Assembly 1 12 90821 O Ring 1 1...

Страница 28: ...m mb bl ly y PART DESCRIPTION QUANTITY 1 93810 Injector Screen 1 2 93223 Injector Throat 1 3 93220 Injector Seal Thick 1 4 93221 Injector Nozzle 1 5 93232 Top Injector Seal Thin 1 6 93222 Injector Cap...

Страница 29: ...th sides is the one that creates the injection stream that enters the Throat It is important that this hole is clear of debris round and undamaged If this hole becomes clogged do not use anything such...

Страница 30: ...cludes O Ring Spring 1 2 90821 O Ring 1 3 93260 Housing 1 4 90843 0 5 gpm Flow Control 1 5 93805 O Ring 1 6 93243 Housing Cap 1 7 90807 Screw 2 93601 Entire Assembly all of the above parts B Br ri in...

Страница 31: ...ar rt ts s S Sa af fe et ty y S Sh hu ut to of ff f A As ss se em mb bl ly y PARTS DESCRIPTION QUANTITY 1 54226 Safety Shutoff 1 2 56018 Float 1 3 56200 Air Check 1 56024 Entire Assembly all of the ab...

Страница 32: ...c insert Screw the nut on the elbow body With a wrench tighten the nut securely to create a water tight connection S Sa af fe et ty y S Sh hu ut to of ff f V Va al lv ve e E El lb bo ow w I In ns st t...

Страница 33: ...s to ensure that the correct rate is being used for a particular model Refer to Specifications When assembling the flow control ensure that the rounded side of the hole faces in toward the water flow...

Страница 34: ...free of defects such as pits or scratches and also free of debris When assembling the End Cap to the Valve Body care should be taken to make sure that the O ring stays in the groove in the End Cap If...

Страница 35: ...he service position Check that appliance is plumbed correctly Initiate manual regeneration Reset Time of day if set to Time Mode 1 or Demand Delayed Mode 2 Re test the water and re enter a new setting...

Страница 36: ...See Specifications Remove restriction Remove restriction replace if crimped Verify correct water level relative to salt setting Check brine line and fittings for loose connections Check mode setting c...

Страница 37: ...service flow rate of 4 gpm 15 1 Lpm 4 5 psi 0 3 bar Maximum flow rate to drain during regeneration backwash 2 4 gpm 9 1 Lpm Water Pressure minimum 20 psi 1 4 bar Water Pressure maximum 120 psi 8 3 ba...

Страница 38: ...iron algae sulphur tannins organic matter or other unusual substances then unless the system is represented as being capable of handling these substances in the system specifications other special tr...

Страница 39: ...37 N No ot te es s...

Страница 40: ...Copyright 2009 Maximizer 400 4343 S Hamilton Rd Groveport OH 43125 LITHO USA Form RV0209TL I In n B Bu us si in ne es ss s S Si in nc ce e 1 19 95 56 6 400...

Отзывы: