Troubleshooting 

Problem 

Possible Cause 

Solution 

No salt in brine cabinet 

Add salt 

Sediment in brine cabinet has plugged the 
brine line and air check/draw tube 

Remove the brine line and flush clean 
Remove the air check/draw tube and flush with 
clean water. Clean injector assembly. Clean 
any sediment from brine cabinet

 

Flow control is plugged 

Remove brine piston housing and clear debris 
from the flow control 

Drain line is pinched, frozen, or restricted 

Straighten, thaw, or unclog the drain line 

Clogged injector assembly 

Remove injector cap and clean nozzle and 
throat with a wooden toothpick. Replace throat 
if removed 

No soft water after 
regeneration 

Salt bridge has formed due to high humidity 
or the wrong kind of salt 

Test with a blunt object like a broom handle. 
Push the handle into the salt to dislodge the 
salt bridge, or use hot water around the inside 
perimeter to loosen salt 

The bypass valve is in the Bypass position 

Place the bypass valve in the Service position 

Appliance is plumbed backward 

Check that appliance is plumbed correctly 

Extended power outage 

Reset the time of day 

Water hardness has increased 

Re-test the water and re-enter a new setting 
number 

No soft water 

Not metering water 

Flow should be indicated with water usage. If 
no flow, see below 

The bypass valve is in the Bypass position 

Place the bypass valve in the Service position 

Appliance is plumbed backward 

Check that appliance is plumbed correctly 

No flow is indicated 
when water is flowing 

Sensor not receiving signal from magnet on 
turbine 

Remove sensor from bypass housing. Test 
with magnet on either flat side of sensor. If 
flow is indicated, check turbine. If no flow, 
replace sensor 

Flow indicated when 
water is not being used 

The household plumbing system has a leak 

Repair the leak 

Electric cord is unplugged 

Plug in the transformer 

No electric power at outlet 

Check power source. Make sure outlet is not 
controlled by a switch 

Defective transformer 

Test with volt meter for 12 VAC at control. If 
less than 10 VAC or greater than 14 VAC, 
replace the transformer 

Defective circuit board 

With 12 VAC present at controller, replace the 
controller 

No read-out in display 

High ambient room temperature. If the 
temperature exceeds 120°F, the display will 
blank out. This does not affect the operation 
of the controller 

No action necessary 

HomeGuard

®

 Owner’s Manual 

9/29/2009 

33 

Содержание HomeGuard 400

Страница 1: ...O OW WN NE ER R S S M MA AN NU UA AL L A AN ND D I IN NS ST TA AL LL LA AT TI IO ON N G GU UI ID DE E V VE ER RS SI IO ON N 1 1 1 1...

Страница 2: ...tances then unless the system is represented as being capable of handling these substances in the system specifications other special treatment of the water supply must be used to remove these substan...

Страница 3: ...ings 8 INSTALLATION AND MAINTENANCE INFORMATION 9 Checklist Before Installation 9 Precautions 10 Installation Steps and Start Up Procedures 11 Bypass Valve 16 Optional Plumbing Procedures 16 Setting a...

Страница 4: ...n independent Hague dealer install and maintain this appliance Note The manufacturer reserves the right to make specification and product changes without prior notice This manual is for installation o...

Страница 5: ...isinfected with 5 25 sodium hypochlorite which is the active ingredient in household chlorine bleach To disinfect the appliance add 0 5 fluid ounces of chlorine bleach solution to the brine well of th...

Страница 6: ...he language mode water hardness and time of each regeneration step Service Settings must be set before Customer Settings Otherwise some values may not be available Service Settings Mode is intended fo...

Страница 7: ...o save a value and display the next value to be changed 1 To program Service Settings press and hold both the Display button and the Select button for about five seconds while Service Setting is displ...

Страница 8: ...e check your controller for the correct time Make any necessary corrections tep 2 Set Regeneration Time Display reads Reg Time followed by the current regeneration time that is set the cursor will be...

Страница 9: ...ally available resin bed cleaner should be used every six months Follow the instructions on the container The hardness setting increases by 4 grains per gallon for every 1 mg L ppm of ferrous iron pro...

Страница 10: ...4 inch I D On municipal water recommended minimum inlet pipe size is 1 2 inch I D 6 Install a gravity drain on the cabinet 7 Secure the drain line on the appliance and at the drain outlet See Install...

Страница 11: ...crawl space and outside installations For under counter kitchen sink consult the factory for recommended instructions G For most installations install the appliance after the pressure tank and any wat...

Страница 12: ...ings are provided with your appliance Qest fittings provide a convenient easy to use three piece assembly for 3 4 inch copper plumbing or 3 4 inch CTS CPVC plastic tubing Ensure that the three compone...

Страница 13: ...The size cannot be reduced B Route the drain line to a floor drain laundry tub or other suitable waste receptor Maintain a minimum 2 inch air gap between the drain line and the flood level rim of the...

Страница 14: ...Setting and Using the Controller Figure 9 Service Position Figure 10 Connect Transformer Power Cord Step 10 Add Water to the Brine Cabinet A Remove any packaging or installation materials Do NOT remo...

Страница 15: ...loride when iron and or manganese are present in the raw water supply is not recommended Figure 11 Fill Brine Cabinet With Salt Step 12 Complete the Installation A Ensure that the bypass is left in th...

Страница 16: ...preparing the male threaded fittings of the I O adapter use the following guidelines to avoid damage to the plastic pipe threads A Wrap the threads three times with 1 2 in wide Teflon tape Place each...

Страница 17: ...pipe and fitting sockets and remove dirt grease or moisture with a clean dry cloth If wiping fails to clean the surfaces use a chemical cleaner Check for possible damage such as splits or cracks and r...

Страница 18: ...tion mode and will display the status of each cycle After all regeneration cycles are complete the display will return to Normal operating mode 2 The Regenerate button can be used to quickly advance t...

Страница 19: ...water that was tested 00 to 99 ppm mg L This value is used to calculate compensated hardness automatically Mang ppm 00 Amount of manganese in parts per million of incoming water 00 to 99 ppm mg L Thi...

Страница 20: ...the values are saved and the controller returns to Normal operating mode Operating Modes The appliance has two operating modes Timer mode and Meter Delayed mode Both modes are equipped with Capacity...

Страница 21: ...if iron present yes 1 1 Salt Setting Backwash 1 minutes 0 Brine Rinse minutes 9 Backwash 2 minutes 2 Capacity grains salt lb 4 900 1 lb 2 Salt Setting Backwash 1 minutes 0 Brine Rinse minutes 12 Backw...

Страница 22: ...net and Cover Assemblies Figure 15 Controller Tab Lock Detail Part Description Quantity 1 55300 Valve Cover Assembly 1 2 93245 Transformer 115V 1 3 54550 Computer Control Assembly 1 4 56004 Cabinet 1...

Страница 23: ...d Cap 1 4 93808 O Ring 2 5 V185 Drain Fitting 1 2 12 7 mm 1 6 93842 Drain Hose 8 2 4 m 1 7 93838 O Ring 2 8 54512 Bypass Assembly 3 4 IO Assembly Shown 1 9 C0700A Cabinet Overflow 1 10 95301T Drive En...

Страница 24: ...ription Quantity 1 93810 Injector Screen 1 2 93223 Injector Throat 1 3 93220 Injector Seal Thick 1 4 93221 Injector Nozzle 1 5 93232 Top Injector Seal Thin 1 6 93222 Injector Cap 1 7 90807 Screw 4 935...

Страница 25: ...e flush on both sides is the one that creates the injection stream that enters the Throat It is important that this hole is clear of debris round and undamaged If this hole becomes clogged do not use...

Страница 26: ...ston Slide Cam Cover 1 7 93217 Piston Slide Cam 1 8 93583 Drive End Cap 1 9 54202 Piston Slide 1 10 90818 Screw self tapping 2 11 93601 Brine Valve Housing Assembly 1 12 90821 O Ring 1 13 54502 Magnet...

Страница 27: ...e Cam 93583 Drive End Cap Seals the two openings on the Main Valve Body The larger diameter opening is sealed with an O Ring used as an axial or face seal The O Ring sits in a groove in the End Cap Th...

Страница 28: ...rt Description Quantity 1 54512 Bypass Assembly 1 2 93860 Turbine Sensor Assembly 1 3 90809 Sensor Cap Screw 1 4 54320 Plastic Turbine Axle 1 5 90522 Turbine Assembly 1 6 93838 O Ring 2 54512 Entire A...

Страница 29: ...the Brine Piston 53511 is a concave seat area that must be free of defects such as nicks indentations or debris This seat area ensures a leak free seal for the static O Ring on the Brine Piston If an...

Страница 30: ...groove in the End Cap If misaligned the O Ring can become pinched and leak H2086 Drain Line Flow Control The Drain Line Flow Control DLFC maintains a constant plus or minus 10 backwash flow rate at v...

Страница 31: ...fety Shutoff Assembly Figure 22 Safety Shutoff Assembly Part Description Quantity 1 54226 Safety Shutoff 1 2 56018 Float 1 3 56200 Air Check 1 56024 Entire Assembly all of the above parts HomeGuard Ow...

Страница 32: ...ty 1 54112 1 2 Compression Assembly 1 2 54138 3 8 Compression Assembly 1 The nut gripper and retainer sleeve are a three piece assembly that can come apart if removed from the elbow body Parts must be...

Страница 33: ...he time of day Water hardness has increased Re test the water and re enter a new setting number No soft water Not metering water Flow should be indicated with water usage If no flow see below The bypa...

Страница 34: ...at if removed Magnet disk defective Replace magnet disk Not regenerating in proper sequence Defective controller Replace controller Plugged injector Replace injector screen nozzle and throat Low water...

Страница 35: ...Water Pressure maximum 120 psi 8 3 bar Minimum water flow required 2 4 gpm 9 1 Lpm Controller type 5 Button Regeneration time 1 lb 0 45 kg salt setting 12 minutes Regeneration time 2 lb 0 91 kg salt...

Страница 36: ...are FDA or NSF listed The appliance conforms to NSF ANSI 44 for softening performance efficiency Barium reduction and Radium 226 228 reduction as verified and substantiated by test data Barium Radium...

Отзывы: