15
20
Spinner Jumper Settings:
* Pull-Ups - Spinners that require outputs to be pulled up to +5V
may be accommodated by placing the jumper on to the center pin
and the pin at the bottom of the header (active low).
* Pull-downs - Spinners that require outputs to be pulled down to
logic ground may be accommodated by placing the jumper on to
the center pin and the pin at the top of the header (active high).
Joystick Axes
The section labeled “Joystick Axes” is
used to configure the potentiometer
inputs for each joystick axis. By
default, all of the axes are disabled
(see the picture to the right).
Each axis can be individually enabled as needed by checking the
“Enabled Joystick Axis” boxes.
Important: Only select a particular joystick axis if that axis has a
potentiometer connected to the corresponding KE-USB108 joystick
header.
File Menu Selections
The file menu selections,
located within a dropdown
list, as shown to the left, are
accessed by clicking on “File”
in the upper left corner of the
main program screen. This
list provides several options
that include creating and
saving file configurations as
well as reading and writing
to the KE-USB108.
dialog will appear as shown below.
The “Delay” tab shown on the previous page is used to create a
delay between steps by entering the desired delay time in the textbox
that appears. Delay times may be set in 10 msec increments from
10 to 2550 msec. The default delay is 10 msec. To change the
delay time simply click on the time delay box and enter the new
time. When the desired time is set, click the OK button located
in the lower right hand side of the window to return to the macro
dialog.
If a delay greater than 2.550 sec is required then multiple delay
cells may be defined side by side. The final delay time will be the
sum of the times displayed in the adjacent delay cells.
Complete the following steps to delete an unwanted key, mouse,
joystick or delay event.
1. From the macro dialog click on the cell that contains the event
to be deleted.
2. Make sure the keyboard dialog is selected and if it is not then
click the “Keyboard” tab.
3. Click the “Not Used” button.
Macro Repeat:
In the lower left-hand corner of the macro dialog is an option
for repeating the activation sequence. When the box marked
“Repeat activation sequence” is checked, the activation sequence
will repeat itself from the time the input is made until the input
is released. A report interval ranging from 0.0 to 3.0 seconds
can be selected by using the dropdown list located below the
repeat activation sequence checkbox. By default, the activation
sequence is not repeated. When the repeat activation sequence
box is checked the report interval defaults to 0.5 seconds.
Note: The “repeat with no delay“ option in the repeat activation
dropdown list should only be used in special cases and should not
normally be selected.
Содержание KE-USB108
Страница 1: ...KE USB108 PC Keyboard Encoder User Manual ...