MD3
25-3
The right and left level cylinders must also be
within range to cradle the booms. If the cylinders are
not within the given range, the green light immedi-
ately right of the range specifications will not be lit (A).
If the light is not illuminated and the main horizontal
extension button is pushed a message will appear
reminding the operator to raise the level cylinders to
within the specific range (B).
A
B
Break-away Warning (center cylinder)
This warning will appear immediately after the
engine is engaged. Once the F2 (OK) button has
been pressed the boom will automatically cycle the
break-away cylinder. Make sure before pressing this
button that there are no obstructions or persons in the
way of the boom movement.