background image

4

Hägglunds hydraulic industrial and marine mo tor COMPACT is of the radial-pis ton type with a ro ta ting 
cylinder block/hollow shaft and a stationary housing. The cylinder block is mounted in fi xed rol ler bearings 
in the housing. An even number of pis tons are radially located in bores in si de the cy lin der block, and the 
valve plate directs the incoming and outgoing oil to and from the working pis tons. Each pis ton is working 
against a cam roller.

When the hydraulic pressure is acting on the pis tons, 
the cam rollers are pushed against the slope on the 
cam ring that is rigidly connected to the housing, 
thereby producing a torque. The cam roll ers transfer 
the reaction force to the pistons which are guided in 
the cy lin der block. Ro ta tion therefore occurs, and 
the torque available is pro por tio nal to the pressure 
in the system.

Oil main lines are connected to ports A and C in 
the connection block and drain lines to ports D1, 
D2 or D3 

 

in the motor housing.

The motor is connected to the shaft of the dri ven 
machine through the hollow shaft of the cy lin der block.The torque is 
transmitted by using a mechanical shrink disc, or alternatively by splines. 
The symmetrical design of the motor has made it possible to design it as a two dis pla ce ment mo tor. This 
means that two dif fe rent displacements and speeds can be obtained for a given fl ow. To get the 2-speed 
function, a motor prepared for two speeds has to be ordered together with a 2-speed valve.

Functional description

1

2

3

4

5

6

7

  

D

 

8

 A, 

C

  

10

 

 

9

  

11

Quality

To assure our quality we maintain a 
Quality Assurance System, certifi ed 
to stan dard ISO 9001, EN 29001 and 
BS 5750; Part 1.

1. Cam ring
2. Cam roller
3. Piston
4. Shaft coupling
5. Cylinder block / hollow shaft
6. Cylinder block / spline
7. Shaft end housing
8. Cylinder roller bearings
9. Connection block
10. Valve plate
11. Cylinder roller thrust bearing

A = Inlet or outlet port »A«    
      (2 each)
C = Inlet or outlet port »C«
D = Drain port (3 each)
F4 = Flushing

1

2

3

5

10

Fig. 1

 

 Compact motor

Valid patents

US 4522110, US 005979295A, SE 
456517, EP 0102915,  JP 83162704, GB 
1385693, EP 0524437.

  

F4

Содержание Compact Series

Страница 1: ...Product Manual COMPACT EN396 8h 2004...

Страница 2: ...develop manufacture market complete drivesystems and components of the highest quality based upon our unique radial piston motors Our industrial and marine customers are to be found all over the world...

Страница 3: ...k loads The new Compact has everything you have come to expect from a H gglunds motor high torque wide speed range shock resistant easy to install easy to maintain and as tough as they come Only small...

Страница 4: ...in the motor housing The motor is connected to the shaft of the driven machine through the hollow shaft of the cylinder block The torque is transmitted by using a mechanical shrink disc or alternativ...

Страница 5: ...153 3 2034 230 350 5000 CA 50 191 6 2543 200 280 5000 95 8 1271 200 280 1 2 CA 70 40 153 3 2034 270 400 5000 CA 70 50 191 6 2543 225 320 5000 95 8 1271 225 320 1 2 CA 70 60 230 1 3051 195 275 5000 11...

Страница 6: ...lled in by H gglunds Painting Orange Other Standard Option MDA 14 and MDA 21 designed for separate mounting on the driven shaft MDA 14 can be mounted directly to the motor via Tandem kit 21 this is no...

Страница 7: ...r Mounting set for speed encoder 2 Speed valve P D B 1 1000 Speed encoder Digital Generation Type of encoder Pulse rate pulse rev 1000 3600 Standard 1 Explosion proof 2 Example S P D B S S M C B 1 0 0...

Страница 8: ...2236 278 2238 or 278 2239 For control of spline see table 2 Motor CA50 70 CA100 140 CA210 Toth profile and bottom form DIN 5480 DIN 5480 DIN 5480 Tolerance 8f 8f 8f Guide Back Back Back Pressure angle...

Страница 9: ...025 0 0 00098 0 0 00098 0 0 025 0 0 00098 0 0 025 Note The dimensions are valid for 20 C 86 F F F A CA 50 210 D E F G M20 17 0 67 25 0 98 50 1 97 UNC 5 8 13 5 0 53 22 0 87 30 1 18 Steel with yield st...

Страница 10: ...A210 81 178 Torque arm Max torque Nm For alternating or pulsating torque Max torque Nm At static torque TCA 5 for CA50 17500 21000 TCA 7 for CA70 24500 29400 TCA 10 for CA100 35000 42000 TCA 14 for CA...

Страница 11: ...ment MDA 5 10 0 2 lit 0 06 US gal MDA 14 21 Min 0 2 lit 0 06 US gal MDA 14 21 Max 0 3 lit 0 08 US gal Max speed 100 rpm peaks up to 220 rpm Braking torque dynamic with friction coefficient 0 12 MDA 5...

Страница 12: ...ype VTCA 600 The 2 speed valve is designed for use with Compact motors CA 50 CA 210 The valve has displacement shifting function and is mounted directly on the motor When ordering motor prepared for 2...

Страница 13: ...ith Compact motors CA 50 CA 210 The valve is bolted directly on the motor and the valve protects the motor and system from too high pressure if the motor is suddenly stopped The relief valves have a s...

Страница 14: ...50 CA 70 60 CA 100 80 CA 140 80 CA 70 50 CA 50 40 CA 100 64 CA 70 40 CA 50 32 CA 100 50 Compact motors Double port connection 4 ports 0 2 4 6 8 10 12 14 16 18 20 0 50 100 150 200 250 300 350 400 Speed...

Страница 15: ...16 18 20 22 24 0 20 40 60 80 100 120 140 160 180 rpm kNm 0 2000 4000 6000 8000 10000 12000 14000 16000 lbf ft 96 95 94 93 92 91 90 50 kW 100 kW 150 kW 0 2 4 6 8 10 12 14 16 18 20 22 24 0 20 40 60 80 1...

Страница 16: ...ut power from the motor For continuous duty in applications with an ambient temperature of 20 C 68 F the motor case must be flushed when the output power exceeds the values shown below Fig 21 Flushing...

Страница 17: ...200 250 300 350 400 pressure loss psi CA 50 Pressure loss 4 port 0 5 10 15 20 25 30 35 40 0 50 100 150 200 250 300 350 400 speed rpm pressure loss bar 0 50 100 150 200 250 300 350 400 450 500 550 pres...

Страница 18: ...the average values When calculating volumetric losses using other viscosities multiply the value given in the diagram by the factor K in diagram 20 Diagram 30 Pressure loss oil viscosity 40 cSt 187 SS...

Страница 19: ...g 24 Motor with through hole for cooling of driven machine Fig 28 Direct mounted winch drum drive with brake Fig 26 Bracket mounted capstan drive Fig 22 Torque arm mounted motor with splines Fig 25 Fl...

Страница 20: ...upling a 0 mm Fr kN Fr lbf Diagram 33 Motor type CA 100 and CA 140 Fr kN Fr lbf Diagram 34 Motor type CA 210 L10h 1000 hrs L10h 5000 hrs L10h 20000 hrs L10h 1000 hrs Fr kN Fr lbf Diagram 32 Motor type...

Страница 21: ...80000 90000 100000 110000 120000 0 50 100 150 200 250 300 350 400 450 500 550 600 200 150 100 50 0 50 100 150 200 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 130000 0...

Страница 22: ...uid The following fluids are tested for H gglunds motors ISO DP 6071 Vegetable fluids give good lubrication and small change of viscosity with different temperature Vegetable fluids must be controlled...

Страница 23: ...ntamination level When choosing the filter it is important to consider the amount of dirt particles that the filter can absorb and still operate satisfactory For that reason we recommend a filter with...

Страница 24: ...8 ft A weighted emission sound pressure level dB A weighted emission sound pressure level dB CA 50 70 CA 100 210 A weighted sound power level B A weighted sound power level B CA 50 70 CA 100 210 Backg...

Страница 25: ...ty Example of the Declaration of Conformity given by H gglunds Drives AB The Declaration of Conformity above is available on request for deliveries from H gglunds Drives AB Translations into other lan...

Отзывы: