background image

5

1.2 Description of display

C

F

flat

needs
charging

charging
recommended

fully charged

charging

Scrolling text zone: 

- display of time
- outdoor temperature
- faults
- access calling
- current commands
- handset mode

Fault

Handset in inter-handset
communication mode

Handset battery status

Handset 
in silent mode

Communication in progress

Missed call

no signal

poor

average

good

excellent

Radio range

lighting off

lighting on

Lighting status

Garage, side gate and latch status

gate closed

gate open

gate 1 open/2 closed 
or gate half open 
if sliding motor

gate 1 closed/2 open 
or side gate open

latch closed

latch open

Garage status

Indoor temperature 
indication

Temperature unit:

- °C: Celsius
- °F: Fahrenheit

Indoor temperature

garages
closed

garages 
open

garage
1 open
2 closed

garage 
1 closed
2 open

IMPORTANT: only the icons
corresponding to the
installation are displayed.

Содержание LCP02U

Страница 1: ...User guide GB LCP01U LCP02U LCP03U LCP04U LCA01U LCB01X MHF01X MHF02X MHF03X MHF04X MHF05X MHF06X Doorphone 805012 B...

Страница 2: ...e or several automatic garage door control systems one or several lights It also allows users to check the status of access points or lights using the screen on the handset at any time Several additio...

Страница 3: ...ay options 26 11 5 Modifying sound options 27 11 6 Modifying control options 28 11 7 Modifying opening options 29 11 8 Information 29 12 Modifying handset operating options 30 12 1 How to browse throu...

Страница 4: ...n Validate button OK Gate control button Inter handset communication button Latch side gate control button Garage control button 1 Lighting control button 1 Up and down scroll keys Left and right scro...

Страница 5: ...Missed call no signal poor average good excellent Radio range lighting off lighting on Lighting status Garage side gate and latch status gate closed gate open gate 1 open 2 closed or gate half open if...

Страница 6: ...The name of the access point calling 2 is displayed C 6 1 3 Handset display in standby mode general information screen 2 Answering a visitor s call IMPORTANT if the handsets or controllers are too cl...

Страница 7: ...tivated communication is established if not press 2 If the handset is already off the base press 2 Open the flip cover to talk and adjust the volume using the keys 3 At the end of communication press...

Страница 8: ...ground sounds at the different access points where the outdoor caller units are installed using the key 1 Quickly press 2 If you have more than 2 access points select the one you wish to listen in to...

Страница 9: ...djusting the communication volume using the keys C C 4 At the end of communication press and or put the handset back on the base At the end of communication press and or put the handset back on the ba...

Страница 10: ...ss 1 C 2 The latch of the access making the call is unlocked within 5 sec At the end of communication the latch status icon is updated if a position contact is connected C 10 6 Controlling latch acces...

Страница 11: ...The latch is unlocked within 5 seconds Open C 1 If a position contact is connected 2 If you press the wrong button press then enter the access code again 3 Only applies to the outdoor caller unit with...

Страница 12: ...s on the base open the flip cover and select the access point to be opened using the keys then Closed Closed C C 3 If you only have one latch access point the opening command is sent directly to it Op...

Страница 13: ...2 The gate at the access point making the call is activated within 5 seconds At the end of communication the gate status icon is updated if a position contact is connected C 13 7 1 When communicating...

Страница 14: ...Mourroux 3 The gate is activated within 5 seconds Open C 1 If a position contact is connected 2 If you press the wrong button press then enter the access code again 3 Only applies to the outdoor call...

Страница 15: ...e several gate access points select the access point to be opened using the keys then Closed Closed C C 3 If you only have one gate access point the opening command will be sent directly to that acces...

Страница 16: ...ess 1 for example C 1 Press C 2 The side gate at the access point making the call is unlocked within 5 sec At the end of communication the side gate status icon is updated if a position contact is con...

Страница 17: ...ux 3 The side gate is unlocked within 5 seconds Open C 1 If a position contact is connected 2 If you press the wrong button press then enter the access code again 3 Only applies to the outdoor caller...

Страница 18: ...cess points pick up the handset if it is on the base open the flip cover and select the access point to be opened using the keys then Closed Closed C C 3 If you only have one side gate access point th...

Страница 19: ...y to it Opening command sent C 3 The garage is activated within 5 seconds Open C 2 1 if a position contact is connected to the output receiver 2 The name of the automatic garage door control system ca...

Страница 20: ...set if it is on the base open the flip cover and quickly press 2 If you have several lights select the light to be switched on using the keys then OFF OFF C C 3 If you only have one light the ON comma...

Страница 21: ...ccess points an additional ACCESS 1 ACCESS 2 menu is displayed here so that you can select the access point whose parameters you wish to change You will access a set of menus allowing you to programme...

Страница 22: ...so that a side gate gate or latch can be opened 16 tags max 1 Pick up the handset and stand in front of the outdoor caller unit 2 Press once on 3 Hold the tag to be registered in front of the name lab...

Страница 23: ...g the keys 3 Move on to the next character using the key 4 Perform steps 2 and 3 for all the characters and then once the desired name has been programmed press C C ACTIVE INACTIVE ACTIVE INACTIVE Act...

Страница 24: ...ble Using the setting ADD Factory no code programmed for the 16 possible codes Can be used to programme an access code on the outdoor caller unit so that a side gate gate or latch can be opened restri...

Страница 25: ...ed 8 characters max 1 Select the code to be modified 2 Modify the 1st character using the keys 3 Move on to the next character using the key 4 Perform steps 2 and 3 for all the characters and then onc...

Страница 26: ...a button is pressed or a tag used Can be used to modify a name given to an access or to a call button 8 characters max 1 Select the name to be modified 2 Modify the 1st character using the keys 3 Move...

Страница 27: ...g is activated when a button is pressed or a tag used the BACKLIGHTING menu is not displayed and no other operating mode is possible BACK LIGHTING cont BUTTON 2 or BUTTON 1 Handset display in standby...

Страница 28: ...by mode RADIO LINK HANDSET ACCESS TAGS PIN DISPLAY SOUNDS PARAMETERS PULSE INFOS AUTO COMMAND Menu Setting possible Using the setting AUTO COMMAND Factory ELECTRIC STRIKE Can be used to define the com...

Страница 29: ...or gate motorisation control terminal blocks 12 and 14 PEDESTRIAN 0 5 SEC 1 SEC 1 5 SEC 2 SEC 2 5 SEC Factory 1 S Can be used to change the pulse duration for gate motorisation pedestrian opening cont...

Страница 30: ...S CONFIGURATION INFOS DISPLAY SOUNDS CONFIGURATION INFOS You will access a set of menus allowing you to programme or modify the doorphone system s parameters Select the option status or value using th...

Страница 31: ...o a Garage control button BACK LIGHTING ACTIVE INACTIVE Activates or deactivates handset backlighting Backlighting is always activated during calls 1 Select the name to be changed 2 Modify the 1st cha...

Страница 32: ...of handset ringing 1 Select the door bell to be changed 2 Choose the desired door bell from among the 9 available and then press Handset display in standby mode RADIO LINK HANDSET ACCESS Handset displ...

Страница 33: ...layed on the handset 1 Set the 1st digit using the keys 2 Move on to the next digit using the key 3 Perform steps 1 and 2 again to set the minutes then once the chosen time has been programmed press C...

Страница 34: ...Move closer to the controller Check that the handset is not in silent mode icon displayed What does the icon displayed on the handset mean A visitor came to the outdoor caller unit while you were out...

Страница 35: ...puts outputs are SELV types Internal handset unit data Interior boxes made of ABS Degree of protection IP31 IK04 Operating temperature from 5 C to 55 C Base powered by mains supply via 220 V 6 V trans...

Страница 36: ...Hager 06 2012 805012 B Hager SAS 132 Boulevard d Europe BP 78 F 67212 OBERNAI CEDEX Tel 333 88 49 50 50 www hager co uk...

Отзывы: