PA:1
- Default duration of the temporary override
This parameter allows you to input a default, restart time delay. Possible delay times are the following:
1 hour, 2 hours, 3 hours, 4 hours, 5 hours and 12 hours. The restart delay is set to 1 hour by default.
•
PA:1
and
flash. Press key
+
or
-
to modify the timed restart delay.
Confirm using the
OK
key to pass to the next parameter.
PA:2
- Backlighting
Backlighting is activated (
on
) by default.
• Press key
+
or
-
to deactivate it (
OF
f
).
Confirm using the
OK
key to pass to the next parameter.
PA:3
- Temperature calibration
This parameter lets you adjust the value displayed by the thermostat if you measure a different
ambient temperature to that which the thermostat measures.
• Press key
+
or
-
to modify the temperature within a range of +/-3 °C.
Confirm using the
OK
key.
PA:4
-
2
nd
Comfort temperature level
This parameter allows you to choose one
or two
Comfort temperature levels. It is only
applicable during programming of the free program (
P4
).
• Press key
+
or
-
to choose
1
to
2
.
Confirm using the
OK
key to pass to the next parameter.
Parameter
PA:4
is set to 1, single Comfort level, by default.
Holiday mode
This mode protects your accommodation
against the dangers of frost and maintains a
minimum temperature during your absences,
which can be adjusted between 5 °C and
30 °C.
You can program the duration of your absence
to anticipate a rise in temperature for your
return.
• Press key
, and then press key
+
to select the number of days absence
(from 1 to 99 days).
The current day counts as 1.
Confirm using the
OK
key.
• The icon
appears and the temperature
to be adjusted flashes.
• Press key
+
or
-
to indicate the desired
temperature level. Confirm using the
OK
key.
Leave the thermostat in this mode. To cancel
and return to automatic mode,
menu
.
• To modify the duration of your absence or
the temperature value, press key
and
proceed to the changes.
If the thermostat is in air conditioning mode,
you can create 1 holiday programme and
define the number of days absence.
The air conditioning will stop.
The ambient temperature will not be regulated.
Heating/Air-con reversibility
This function allows your installation to switch
from Heating to Air conditioning mode.
It requires that parameter
PA:5
in
HC
in the
menu
(Heating/Air-con mode) is set
beforehand.
• Press key
menu
to place the cursor
under .
•
flashes and the thermostat regulates the
heating.
• Press key
to change from Heating
mode to Air conditioning mode.
Programming
Four programs are available to program your
week :
P1
,
P2
,
P3
, , which are pre-recorded and not
modifiable, and
P4
P4 which is free and allows
you to create a personalised program that can be
different for each day of the week.
P1
o
is only available when the optimisation parame-
ter is active (
PA:9
) and
P4a
is only available when
the anticipation parameter is active (
PA:9
). Your
installer will perform the required parameterisation.
Assigning an existing program (P1, P2 or P3)
to one or more days of the week
You can assign any of the programs to all 7 days
of the week, to a group of five weekdays, to a
group of two days for the weekend or to an indivi-
dual day.
• Press key
menu
to place the cursor under
prog
. The indicators for the seven days of the
week flash.
• Press key
+
to select which day, or group of
days, to assign a program to.
Confirm using the
OK
key.
•
P1
flashes. Press key
+
to select the program
to apply.
Confirm using the
OK
key.
As an example, to assign P2 to the group of five
weekdays and P1 to the group of two weekend days:
• Press key
menu
to place the cursor under
prog
. The indicators for the seven days of the
week flash.
Modification of the Comfort 2 temperature
• The Comfort temperature
flashes.
• Press key
+
or
-
to modify the temperature.
Confirm using the
OK
key.
This adjustment is only available if the 2
nd
Comfort
temperature level has been selected in the parame-
ter menu
PA:4
.
Modification of the Eco temperature
• The Eco temperature
flashes.
• Press key
+
or
-
to modify the temperature.
Confirm using the
OK
key.
User parameters
To access the user parameters, press key
menu
to place the cursor under
and confirm using
the
OK
key.
Once adjustment of these 4 parameters is carried out, the thermostat switches to auto mode and
registers these modifications.
P1
= Comfort temperature from
06:00
to
23:00.
Eco temperature from
23:00
to
06:00.
P1
is activated 7 days per week by
default. If this fits the rhythm of your life
then remain in automatic mode; if not,
continue.
P1
o
=
Optimisation
(only with
P1
).
Comfort temperature from
07:00
to
23:00.
Eco temperature from
23:00
to
07:00.
P2
= Comfort temperature from
06:00
to
08:30
and from
16:30
to
23:00.
Eco temperature from
08:30
to
16:30
and from
23:00
to
06:00.
P3
= Comfort temperature from
06:00
to
08:30,
from
11:30
to
13:30
and from
16:30
to
23:00.
Eco temperature from
08:30
to
11:30,
from
13:30
to
16:30
and from
23:00
to
06:00.
P4
= a free program which allows you to create
up to 5 Comfort temperature periods and
5 Eco temperature periods, for each of the
days of the week.
flashes and the thermostat regulates the air
conditioning.
In
HC
mode, care should be taken to switch the HP
suitably for the chosen thermostat mode.
Adjusting the temperature set-points
By default, the thermostat is in Heating mode (
H
)
see
installer parameters PA:5 - Heating/Air-con mode.
- If
PA:5
5 is set to heating only (
H
). The tempera-
tures are preset:
Comfort = 19 °C, Comfort 2 = 20 °C, Eco = 16 °C.
The adjustment range for the heating set-points
is from 5 °C to 30 °C.
- If
PA:5
is set to air conditioning only (
C
).
The temperatures are preset:
Comfort = 24 °C, Eco = 29 °C. The range of
adjustment for the air conditioning set points
is from 20 °C to 30 °C.
- If
PA:5
is set to reversible heating/air conditioning
(
HC
), you can modify the pre-set temperatures for
each mode
and
.
Modification of the Comfort temperature
• Press key
menu
to place the cursor under
.
The Comfort temperature
flashes.
• Press key
+
or
-
to modify the temperature.
Confirm using the
OK
key.
… cont.
PA:10
- Return to factory settings
This parameter lets you return programs and parameters to the factory settings.
• Press key
+
or
-
to choose
Yes
(reset) or
no
(pas de reset).
Confirm using the
OK
key to pass to the next parameter.
PA:12
- Software version
This parameter displays which version of the software is installed in the product.
Press
OK
to exit from parameter adjustments.
Choice of the mode of regulation as a function of the heating/air-conditioning generator.
- ON/OFF regulation: suitable for all types of installation (gas boiler with or without flue, fuel oil boiler,
heat pump, heating/air-conditioning circulation).
- PID regulation: suitable for the following installations: heating or cooling circulation, gas boiler.
The most accurate regulation.
3