Initial adjustment and updating

When the product is first used, the screen offers the
option to adjust the year, date and time, without
going into the parameter settings. 

or

Press key 

menu

to place the cursor under 

.

• The year flashes. Press key 

+

, the navigation key,

to adjust the current year.
Confirm using the 

OK 

key.

• The month flashes. Now press key 

 

+

or 

-

Confirm using the 

OK 

then proceed in the same

manner to select the day, hour and minutes.

• 

AUTO

flashes. Press key 

+

to set the installation

to switch automatically between summer and
winter time (

auto

) or not (

OF

f

). Confirm using the

OK 

key.

• 

24:H

flashes. Press key 

+

and select

the 12 hour or 24 hour time format. 
Confirm using the 

OK 

key.

Automatic mode (auto)

In automatic mode, the thermostat adapts itself to
the rhythm of your life by applying one or more pro-
grams that you have selected.
• Press key 

 

menu

to place the cursor under

auto.

Key 

menu

allows you to return to 

auto 

mode

when the (holiday) program is running or a timed
restart is in progress.

Manual mode (manu)

Manual mode transforms your equipment into a
simple thermostat. It allows you to maintain a
constant temperature in your accommodation
(adjustable from +5 °C to +30 °C) and ignores the
available program profiles.
• Press key 

 

menu

to place the cursor under

manu.

• Press key 

+

or 

-

to adjust the desired tempera-

ture.

Example : the desired temperature is at 22.5 °C and
the ambient temperature is 20 °C.
The heating-activated indicator 15 is illuminated.

Standby mode

The heating and/or air conditioning system can be
put on standby. The thermostat is live and protects
your installation if the temperature drops below 
5 °C (fixed non-modifiable instruction). It displays
the time, current day, ambient temperature and 
Off information.
• Press key 

menu

to place the cursor

under .

OF

f

flashes.

• Confirm using the 

OK

key.

• Press key 

menu

to exit standby mode.

From air conditioning mode, standby mode 
represents a stop command and the ambient 
temperature is no longer regulated.

PA:1

- Default duration of the temporary override

This parameter allows you to input a default, restart time delay. Possible delay times are the following:
1 hour, 2 hours, 3 hours, 4 hours, 5 hours and 12 hours. The restart delay is set to 1 hour by default.
• 

PA:1

and 

flash. Press key 

+

or 

-

to modify the restart delay.

Confirm using the 

OK 

key to pass to the next parameter.

PA:2

- Backlighting

Backlighting is activated (

ON

) by default. 

• Press key 

+

or 

-

to deactivate it (

OF

f

).

Confirm using the 

OK 

key key to pass to the next parameter.

PA:3

- Temperature calibration

This parameter lets you adjust the value displayed by the thermostat if you measure a different
ambient temperature to that which the thermostat measures.
• Press key 

+

or 

-

to modify the temperature within a range of +/-3 °C.

Confirm using the 

OK 

key to pass to the next parameter.

PA:4

- 2

nd

Comfort temperature level

This parameter allows you to select one 

or two 

Comfort temperature levels. It is only applicable

during programming of the free program (

P4

).

• Press key 

+

or 

-

to choose 

1

or 

2

.

Confirm using the 

OK 

key to pass to the next parameter. 

Parameter 

PA:4

is set to 1 single level of Comfort by default.

PA:5

- Heating/Air-con mode

This parameter allows you to put your installation into Heating mode (

H

), Air conditioning mode (

C

or reversible Heating/Air-con mode (

HC

) (the icon  

is displayed). 

• Press key 

+

or 

-

to select 

H

C

or 

HC

Confirm using the 

OK 

key to pass to the next parameter. 

Parameter 

PA:5

is set to heating 

H

) by default. 

In 

HC 

mode, care should be taken to switch the HP suitably for the chosen thermostat mode.

PA:6

- Degumming the pump

This parameter allows you to activate/deactivate the automatic start-up of the pump at midnight
everyday, in order to avoid its jamming during the summer.
• Press key 

+

or 

-

to activate (

ON

) or desactivate (

OF

f

).

Confirm using the 

OK 

key to pass to the next parameter. 

Parameter 

PA:6

6 is set to 

OF

f

by default.

PA:7

Type of heating regulation

This parameter lets you define the type of inertia of your heating installation. 
• Press key 

+

or 

-

to select :

On/OF

f

= On or off (default setting). The differential is less than 0.3°C (factory setting).

FA

S

= PID regulation for installations with rapid inertia (radiator). 

Minimum run time 1 minute (10% of the cycle time).

SL

o

= PID for installations with slow inertia (underfloor heating). 

Minimum run time 2 minutes (10% of the cycle time).

• Confirm using the 

OK

key to pass to the next parameter.

In On/Off regulation, only the anticipation function is available, see 

PA:9

In PID regulation, the optimisation and anticipation functions are available, see 

PA:9

.

PA:8

- T

ype of regulation for air conditioning

As 

PA:7

but 

FA

S

used for convector fan and 

SL

o

for underfloor cooling.

PA:9

- Optimisation and anticipation

This parameter allows you to activate an optimisation or anticipation function which is deactivated
(

OF

f

) by default.

The optimisation function is only available with PID regulation, see 

PA:7

or 

PA:8

The anticipation function is available with on/off and PID regulation.

Optimisation

: he thermostat automatically estimates the time required

to reach the Comfort temperature and adjusts the switch-on time of the
heating so that the desired temperature is attained at the desired time.
A period of around 10 days is necessary to train the installation because
it depends on the type of inertia of your heating. 

Note

: only 

P1

o

benefits from the optimisation function. 

• Press key 

+

to activate (

AUT

) the optimisation function. 

Confirm using the 

OK

key to pass to the next parameter.

16 °C

18 °C

20 °C

7 h

x

H

(automatic calculation)

In reversible heating/air-conditioning mode (select 

HC

for parameter

PA:5

); it is possible to select a different mode of regulation for each 

system.
The heating may be configured as on/off and the air conditioning as PID
regulated. In this case, the optimisation function and program 

P1

o

can

only be applied during PID regulated air-conditioning.

Anticipation

: this function allows the Comfort 

or Comfort 2 

temperature from the personalised program (

P4

) to be applied, in

advance, for a configurable period of 1, 2 or 3 hours.

Note

: only 

P4a

benefits from the anticipation function.

• Press key 

+

to select the duration (

1H

2H

ou 

3H

) of anticipation

desired, (e.g. anticipation of 2 hours).
Confirm using the 

OK

key to pass to the next parameter.

16 °C

18 °C

20 °C

6 h

2H

2

Installer parameters

To access all the parameters (from 

PA:1

to 

PA:12

), press key 

menu

to place the cursor under 

and then give one long press (>5s) on 

OK

.

To only access parameters from (

PA:1

to 

PA:4

), press key 

menu

to place the cursor under 

and confirm using the 

OK

key.