Wiring Details & Functions (ALL OPTIONS SHOWN)
REQUEST TO EXIT
KEY SWITCH OR
ACCESS
CONTROL
SYSTEM
(OPTIONAL)
REMOTE RESET
SWITCH
(OPTIONAL)
REMOTE
STATUS PANEL
(OPTIONAL)
FIRE
ALARM
INPUT
(OPTIONAL)
POWER
SUPPLY
12VDC
OR 24VDC
Dry,
N/C
BLK
RMB X L3
RED
EXTERNAL
TRIGGER
SWITCH
OR
SDC REX PUSH BAR
(OPTIONAL)
DOOR POSITION
SWITCH
(DPS)
BOND ALERT (BAS)
[DPS]
N/O
COM
N/C
[ATS]
ANTI-TAMPER SWITCH
(ATS)
MONITORING OPTIONS
N/O
COM
N/C
N/O
COM
N/C
GR
N
SMOKE DETECTION
SYSTEM INPUT
(OPTIONAL)
Dry,
N/C
INSTANT
BYPASS
OVERRIDE
(OPTIONAL)
[PWR]
[FP]
[LOCK]
[GRN
RLY]
[RED
RLY]
[RM TRIG]
[RESET]
[REX]
12 VDC OR 24 VDC
TO CLOSED FIRE/SMOKE
DETECTOR CONTACT
SLAVE/TANDEM LOCK
POWER TERMINALS
LOCK SECURE
OUTPUT
ALARM OUTPUT
EXTERNAL TRIGGER
SWITCH INPUT
EXTERNAL RESET SWITCH
INPUT
REQUEST TO EXIT
INPUT
[IBO]
INSTANT BYPASS OVERRIDE
INPUT
N/O
COM
JUMPER
J6
(SEE PG
9)
C NC
- +
-
+
NC
NO
NO
C
C
NC
NO
C
NO
C
NO
C NO C
NO
C
NC NO C NC
[ BAS
]
[ DPS
]
[RESET
]
[RM
TRIG]
[REX]
[RED
RLY]
[GRN RLY]
[ LOCK
]
[ FP ]
[ PWR
]
J
6
J
7
J
2
[IBO]
[EXT
SPKR]
REMOTE
SPEAKER
(OPTIONAL)
2958 Delayed Egress MagLock
Installation Instructions
S-EA00051
TERMINAL BOARD CONNECTIONS
POWER IN -
POWER IN +
COM
N/C
AUX LOCK -
AUX LOCK +
N/O
COM
N/C
N/O
COM
N/C
N/O
COM
N/O
COM
N/O
COM
[MBS]
3/28/12
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 ● (800) 325-9995
8