background image

Page 6 of 8

2916P Proximity Keypad

Installation Instructions

I-EA00130

Rev 6, Rev Date: 5/29/19

Always visit www.hagerco.com for the latest Installation Instructions

HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995

Beep Sounds During Auxiliary Relay                    Default: No

Selects whether or not the keypad beeps during Auxiliary Relay 
activation.

Press: 42 # 

Sound

 

 #  

Sound=1 for Yes, =0 for No

Beep Sounds During Output #3                             Default: No

Selects whether or not the keypad beeps during Output #3 
activation.

Press: 43 # 

Sound

 

 #  

Sound=1 for Yes, =0 for No

Beep Sounds During Output #4                             Default: No

Selects whether or not the keypad beeps during Output #4 
activation.

Press: 44 # 

Sound

 

 #  

Sound=1 for Yes, =0 for No

Anti-Pass Back Time

            Default: No Anti-Pass Back

Sets the length of time an entry code will not function after it is 
used.

Press: 51 # Minutes

 

 #  

Minutes=Time in minutes (2-4), 0=No Anti-passback

RESETTING KEYPAD

Master Reset

CAUTION:  Performing a master reset will clear the entire 
memory of the 2916P and return all programmable options 
to the factory default values.  ALL ENTRY CODES WILL BE 
ERASED. NOTE:  The Master Code will NOT be reset.

STEP 1

Disconnect power from the keypad.

STEP 2

Press and hold down the * and # keys.

STEP 3

Apply power to the keypad, continue holding the keys 

down until the red indicator starts flashing

STEP 4

Release the keys.  The red and yellow indicators will 

remain lit until the process is complete, then the 

yellow indicator will go out.

Resetting the Master Code

STEP 1

Remove the 2916P from the wall and disconnect 

power from the keypad.

STEP 2 

Locate & Remove jumper at JP2.  Reference page 2.  

STEP 3

Re-apply power.  You will get a single beep and 

the yellow LED will flash momentarily.

STEP 4

Replace jumper on JP2.

THE MASTER PROGRAMMING CODE IS NOW 123456.

Beep Sounds During Main Relay                           Default:  No

Selects whether or not the keypad beeps during Main Relay 
activation.

Press: 41 # 

Sound

 

 #  

Sound=1 for Yes, =0 for No

Solid-state Output #4 On-time                 Default:  02 Seconds

Sets the length of time Output #4 activates when triggered.

Press: 24 # 

Seconds

 

 #  

Seconds=Output time in seconds (1-60), 99=Toggle Mode

Beep Sounds on Keystrokes                                Default:  Yes

Selects whether or not the keypad beeps as each key is pressed.

Press: 40 # 

Sound

 

 #  

Sound=1 for Yes, =0 for No

Selects mode for Keypad LED Backlight      Default: 30 Sec

Selects whether or not the keypad back light stays OFF, lights for 
30 seconds when activated or stays ON.

Press: 52 # Output

 

 #  

 0 = Light always OFF

1 = 30 sec light when activated (default)

2 = Light always ON 

Solid-state Output #3 On-time                 Default:  02 Seconds

Sets the length of time Output #3 activates when triggered.

Press: 23 # 

Seconds

 

 #  

Seconds=Output time in seconds (1-60), 99=Toggle Mode

Beep Sounds Anti-Tamper Activation                    Default: No

Selects whether or not the keypad beeps during Anti-Tamper 
switch activation.

Press: 45 # 

Sound

 

 #  

Sound=1 for Yes, =0 for No

Changing the

 

Beeper Sound Level

The Keypad

s beeper can be set to high or low level.

Remove jumper JP1 to reduce beeper sound level.

Changing the 6-Digit Master Programming Code

  

Press: 98 # 

Master

 

Code

 

 # 

Master Code

 

 #  

Master Code=The new 6-digit Master Programming Code

Keypad Lockout Count                             Default: 3 Attempts

Sets the number or incorrect entry code attempts allowed 
before the keypad 

locks out

” 

for 60 seconds.

Press: 50 # Attempts

 

 #  

Attempts=Number of attempts before lockout (2-7)

*Refer to Option 13 to Enable Lockout Feature

Door Ajar Timer                                        Default:  60 Seconds

Sets the amount of time the door may be held open after an 
authorized access.  The DOOR AJAR output will activate after the 
time expires.

Press: 25 # 

Seconds

 

 #  

Seconds=Held open time in seconds (1-60)

Auxiliary Relay On-time

            Default:  02 Seconds

Sets the length of time the Auxiliary Relay activates when 
triggered.

Press: 22 # 

Seconds

 

 #  

Seconds=Output time in seconds (1-60)

Содержание 2916P

Страница 1: ...nhibit the input can be wired to a normally open service switch or automatic timer that will disable access while the switch is closed The REQUEST TO EXIT input can be wired to a normally open pushbut...

Страница 2: ...ust first enter programming mode to perform any function The yellow indicator will blink slowly showing that the 2916P is in programming mode Use the option codes to program each function After the ne...

Страница 3: ...4 TRIGGERS A NORMALLY OPEN ALARM PANEL ZONE EXAMPLE 2 BLUE PINK SALMON OUTPUT 3 COM OUTPUT 4 COM POWER SOURCE OUTPUT 3 END OF LINE RESISTOR ALARM PANEL NO ZONE COMMON LOW VOLTAGE LAMP BLACK BLACK OUT...

Страница 4: ...Relay 2 Auxiliary Relay 3 Both Relays 10 Relay 1 toggled 20 Relay 2 toggled 30 both Relays toggled 12 Relay 1 toggled Relay 2 timed open 21 Relay 1 timed open Relay 2 toggled The yellow indicator will...

Страница 5: ...4 1 Main Relay 2 Auxiliary Relay 3 Output 3 4 Output 4 0 No Output Lockout Disable Select Alarm Shunt Output Default No Output Sets which output activates during the time access is granted Use this ou...

Страница 6: ...Sounds During Main Relay Default No Selects whether or not the keypad beeps during Main Relay activation Press 41 Sound Sound 1 for Yes 0 for No Solid state Output 4 On time Default 02 Seconds Sets t...

Страница 7: ...Always visit www hagerco com for the latest Installation Instructions HAGER COMPANIES 139 Victor Street St Louis MO 63104 800 325 9995 5 750 1 375 3 000 MOUNTING TO SINGLE GANG RECESSED OUTLET BOX 2X...

Страница 8: ...Rev 6 Rev Date 5 29 19 Always visit www hagerco com for the latest Installation Instructions HAGER COMPANIES 139 Victor Street St Louis MO 63104 800 325 9995 OPTIONAL SHROUD SURFACE MOUNT WITH OPTION...

Отзывы: