Page 4 of 8
2916P Proximity Keypad
Installation Instructions
I-EA00130
Rev 6, Rev Date: 5/29/19
Always visit www.hagerco.com for the latest Installation Instructions
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995
FACTORY DEFAULTS
Master Programming Code
………..…………………….…...123456
Entry Code Length
…………………………………...….……..4
digits
Entry Mode
……..…………………………………....…...
Card or PIN
Request-to-exit Output Relay
………………………..........
No Output
Alarm Shunt Output
……………………………………….....
Disabled
Forced Entry Output
……………………………..…………
No Output
Door Ajar Output
…………………………………..…….….
No Output
Main Relay On Time
………………………………….…..02
Seconds
Auxiliary Relay On Time
…………………………….....…02
Seconds
Solid State Output #3 On Time
……………………….....02
Seconds
Solid State Output #4 On Time
……………………….....02
Seconds
Door Sense/Inhibit Input
…………………………...……..
Door Sense
Keypad Lockout Output
………………………………..…….
Disabled
Keypad Active Output
………………………………..…..…..
Disabled
Beeper Sounds When Key Pressed
……………………...………
Yes
Beeper Sounds During Relay
#1………………………..…...…….
No
Beeper Sounds During Relay
#2……………………………...…...
No
Beeper Sounds During Output
#3……………………………........
No
Beeper Sounds During Output
#4……………………………........
No
Keypad Lockout Count
……….………......….3
Tries Before Lockout
Anti-Passback Time
………………..……….
.
.…….
No Anti-Passback
Auto-Relock
…………………………………...………….………….
On
BASIC PROGRAMMING
When the 2916P is in Programming Mode the yellow indicator will
blink slowly. After a programming command is selected, the
yellow indicator will flash rapidly while the keypad is waiting for
user input data. The green indicator will light if the data is
accepted. The red indicator will light if any programming data is
entered incorrectly, and the command will have to be fully re-
entered. IMPORTANT!:Cards & Codes are stored by User #. It is
imperative that the User numbers and their assigned personnel
are managed in the event a specific user everneeds to be deleted.
Entering Programming Mode
The 6-digit Master Programming Code (default = 123456) is used
to enter Programming Mode.
Press: # 9 # Master Code #
Master Code = the current 6-digit Master Programming Code
Setting Entry Code Length
Default: 4 digits
Press: 03 #
Length
#
Length = 1-6 for entry code length
Note:
If the Entry Code Length is going to be changed from the factory
default of 4 digits, make this change first before programming any entry
codes.
Adding a New User
User PIN Only Access (No Card)
Press: 01 # User #
Code
#
Code # Relay #
---- Or ----
User Card and or PIN Access
Press: 06 # User #
Code
#
Code # Relay # Present Card
User
=3-digit User number to be added: 001-500
Code
=The new entry code: 1-999999, depending on code length
Relay
=Relay output entry code will activate:
1=Main Relay 2=Auxiliary Relay 3=Both Relays
10=Relay #1, toggled 20=Relay #2, toggled 30=both Relays
toggled
12=Relay #1 toggled; Relay #2 timed open
21=Relay #1 timed open; Relay #2 toggled
The yellow indicator will flash quickly while the 2916P stores the
new user information in memory The green indicator will light
when the new code and card are accepted. If the user number
already exists or an entry error has been made, the red indicator
will light. Delete the user and re-enter the new information again.
Note:
Leading zeros (zeros before the code number, i.e.0001) do not
need to be entered when programming a new code. The 2916P will
internally add any zeros to fill digits determined by the entry code length
setting. Leading zeros will have to be entered by the user when entering
their code to gain access.
Output Toggle Mode
When an output is programmed for Toggle Mode, the output
alternates from OFF to ON or from ON to OFF each time it is
accessed. When an output is toggled on, the green LED remains
solid until toggled off.
The rules for a toggle output are:
•
If the output is OFF, it will turn ON and stay on until the next
activation.
•
If the output is ON, it will turn OFF and stay off until the next
activation.
•
An authorized PIN, Card, or REX input programmed to
momentarily activate that same relay will reset the relay to its
normal state.
Re-entering a Command After a Mistake
If the red indicator lights, signaling an incorrect entry, or an
incorrect key is pressed during programming, to clear the keypad
and re-enter the command:
Press:
9 #
*
Adding Multiple Sequential Cards
Press: 08 # 1
st
User
# Code # Code # Relay # Number of
users
# Present 1
st
card
1
st
User =Starting user number to add
Number of users = Total number of consecutive cards to add
After presenting the 1
st
card, the green indicator will light as cards
are added. NOTE: The
“
Code
”
will be the same for all users, but
may be changed for each user using Function 04 below.
Select Entry Mode
Default: Card or PIN
Sets the entry mode for the 2916P.
Press: 05 # Mode #
Mode=Operating Mode(1-3)
1=Card or PIN; 2=Card Only 3=Card and PIN
Exiting Programming Mode
Press:
#
The red indicator will light after exiting Programming Mode
Note:
The 2916P will automatically exit Programming Mode after
30 seconds of inactivity
**
Adding Multiple Non-Sequential Cards
Press: 07 # 1
st
User
# Code # Code # Relay # Number of users
# Present 1
st
card, Present 2
nd
card,
…,
Present last card
1
st
User =Starting user number to add
Number of users = Total number of consecutive cards to add