TRM6.1
Free Field Frequency Response
55Hz–21kHz, ±2dB
Peak Acoustic Output
≥
119dB (per pair w/music @ 1m)
Total Harmonic Distortion (THD)
<0.5%, 150Hz–21kHz (90dB @ 1m on axis)
High Frequency Driver
1" (25mm) Vifa Soft Dome
Low Frequency Driver
6.5" (165mm) Polypropylene Cone/
Inverted Nitrile Rubber Surround
Magnetically Shielded
Cabinet
0.26 ft3 (7.3 liters) Vented
Front Panel:
Power Switch
System LED (Power/Clip/Thermal)
Rear Panel:
XLR Balanced Input
RCA Unbalanced Jack
Unbalanced/Balanced DIP Switch
Input Sensitivity DIP Switches
Bass Rolloff DIP Switches
Bass Shelving DIP Switches
Treble Shelving DIP Switches
IEC Standard Line Input / AC Line Fuse
Dimensions
8.875"W x 13.25"H x 11.50"D
(22.54cm x 33.65cm x 29.21cm)
Net Weight
23 lbs. (10.43kg)
A
MPLIFIER
S
ECTION
Power Rating
FTC (20Hz–20kHz, 0.1% THD)
35 Watts RMS @ 6 ohms (high frequency)
50 Watts RMS @ 4 ohms (low frequency)
Signal-to-Noise
>100dB
CMRR
>70dB typical @ 1kHz
Input Impedance
47k
Ω
per phase balanced, 47k
Ω
unbalanced
Input Sensitivity Range
500mV to 3V (unbalanced)
275mV to 1.5V (per phase balanced)
(+4dB, +1dB, -2dB, -5dB, -8dB, -11dB)
Gain
+33dB max. to +18dB min.
Power Consumption
Idle Power: 11W / 150mA @ 115 VAC
(both channels driven)
Idle Power: 11W / 75mA @ 230 VAC
Normal Operation: 55W / 600mA @ 120 VAC
Normal Operation: 54W / 310mA @ 230VAC
Full Power: 139W / 1.37A @ 120VAC
Full Power: 130W / 680mA @ 230VAC
C
ROSSOVER
S
ECTION
Crossover Frequency
3.2kHz
Crossover Slope
24dB/octave Linkwitz-Riley
Subsonic Filter
Selectable 30Hz or 60Hz @ 12dB/octave
Bass Shelving
30Hz to 200Hz, ±4dB
(+4dB, +2dB, 0dB, -2dB, -4dB)
Treble Shelving
5kHz to 20kHz, ±4dB
(+4dB, +2dB, 0dB, -2dB, -4dB)
P
ERFORMANCE
S
PECIFICATIONS
– i –
Specifications are subject to change without notice.
Frequency Response
@ 1m on axis
Horizontal Polar Response
Energy Time Curve
Dimensions
Содержание TRM6.1
Страница 1: ......
Страница 17: ...Qualified Service Personnel Only 8...
Страница 19: ...Qualified Service Personnel Only 10...
Страница 21: ...PC B OARD L AYOUT Qualified Service Personnel Only 12...
Страница 28: ...TRM6 1 FUNCTIONAL BLOCK DIAGRAM 19...