Network Setup and Maintenance

It is the customer’s responsibility to install, validate, and maintain the network 
and necessary hardware.

In the event of complete loss of the communication network (For example, the 
router fails, the wireless or Ethernet card on the server fails, there is severe 
wireless interference with the network, etc.), a disaster recovery plan is 
recommended. This may include backup hardware and/or a backup paper 
system.

Wireless 
Network Setup 
and 
Maintenance

If the network uses wireless technology, it is the customer’s responsibility to 
ensure that the wireless network has enough capacity to simultaneously 
accommodate a connection to all wireless devices required on the network. 
You should mitigate risks of wireless interference according to the hospital’s 
needs and SOPs.

Monitor the Cell Saver Elite/Elite+ device and other devices for symptoms of 
interference. Interference can be caused by any equipment (Examples: 

microwaves, refrigerators, Bluetooth

® 

devices, fluorescent lights, etc.) that 

operates on the same frequency band. Interference may cause delays, 
timeouts, or lack or access. Relocate equipment, change channels, or follow 
wireless equipment manufacturer instructions to reduce or eliminate 
interference.

Cell Saver Elite/Elite+ devices should be kept a minimum distance away from 
each other (approximately 39 in. [1 m]) to prevent interference of data 
transmission. Also, other electronic devices located in the hospital should be 
kept a minimum distance away from the Cell Saver Elite/Elite+ device. To 
calculate this distance, refer to the IEC/EN 60601-1-2 standard requirements 
located in the user manual.

The performance of the network depends upon proper setup, primarily 
selection of the channel, SSID (network name), and unique IP address of each 
wireless module. Evaluate the network signal level in the room for possible 
conflicting wireless networks and other RF devices in the vicinity. Check the 
signal level periodically and whenever there is an installation of new wireless 
networks or other RF devices.

Creating a 
Network 
Configuration 
QR Code

When configuring the device to communicate with the network, you must scan 

a quick response code (QR Code

®

) that contains all the network configuration 

information. The QR Code must be in plain text format and can be created 
using the CSEliteNetConfig utility. Not all settings are required. The settings 
you must include depend on your network configuration. 

Table 1

 displays the 

wireless authentication options that are supported.

Содержание Cell Saver Elite

Страница 1: ...Connectivity Upgrade User Manual Addendum 120857 US AC June 2017 0123...

Страница 2: ...tain Haemonetics Corporation products This manual should be used in conjunction with instruction and training supplied by qualified Haemonetics personnel Any failure to follow the instructions as desc...

Страница 3: ...onetics Corporation in the United States and or other countries Bluetooth is a registered trademark of Bluetooth SIG Inc QR Code is a registered trademark of Denso Wave Inc DELL and OptiPlex are trade...

Страница 4: ......

Страница 5: ...ctivity 7 Radio Equipment Specifications 7 Wired Connectivity 7 Network Setup and Maintenance 9 Wireless Network Setup and Maintenance 9 Creating a Network Configuration QR Code 9 Configuring the Devi...

Страница 6: ...the end of the procedure The device must receive an acknowledgment from the server application before it marks the data as sent Status update messages The device sends messages to the server applicat...

Страница 7: ...ol Wireless Connectivity The Cell Saver Elite Elite device is equipped with an internal wireless antenna and wireless module communication component that enable the device to communicate with an appro...

Страница 8: ...sion AC Haemonetics Cell Saver Elite Elite User Manual Figure 1 Parts of the device display 2 6 4 1 3 5 7 1 Status beacon 2 Touch screen 3 Barcode reader laser aperture 4 STOP key 5 Touch screen mount...

Страница 9: ...ss Relocate equipment change channels or follow wireless equipment manufacturer instructions to reduce or eliminate interference Cell Saver Elite Elite devices should be kept a minimum distance away f...

Страница 10: ...e Haemonetics Customer Care Center to request access c Locate the CSEliteNetConfig Utility within the designated Cell Saver Elite product area d Click on CSEliteNetConfig Utility e Download the html f...

Страница 11: ...ustomer Care Center by calling 800 537 2802 or by emailing productsupport haemonetics com Configuring the Device The Network Settings screen is password protected and you must have administrator acces...

Страница 12: ...d by Network Connected and then Server Connected once it is connected to the server application 9 Touch Done to return to the System screen Note In the System screen you can also export or import netw...

Страница 13: ...ce data transmission in the network using the Haemonetics HaemoCommunicator software as the data collection application The list is for reference only and is not intended to be a list of required equi...

Страница 14: ...occurs between connected devices on the wireless network power off the router wireless access point for 30 seconds and then power it back on Parameter Value Model D LINK DIR 803 Channels Four 10 100 E...

Страница 15: ...AC Ensure the wireless network router s provide enough capacity to connect to the server Haemonetics devices and other devices that may run at the same time Each of these will use a connection on the...

Страница 16: ...Once the data is marked as sent the procedure record displays the date and time of export If the Cell Saver Elite Elite device is not connected to the server application the device automatically send...

Страница 17: ...record will not be sent to the server application at the end of the procedure In this situation the Procedure Complete message and the status beacon will be yellow instead of green If you access the R...

Страница 18: ...ng determining which fields appear in the Records screen and making a field mandatory Note You must have administrator level access in order to unlock the Options screen To make a field mandatory 1 To...

Страница 19: ...hich will take several minutes Corrective Action Touch Install Update to install the software now or Touch Skip Update to skip the software installation This prompt will recur on the next power up 503...

Страница 20: ......

Отзывы: