ENTIRE SOLUTIONS FOR TRANSFORMERS

Haefely offers a complete product line for transformer tests, both in the factory and on-site.

7

8

6

1

4

1

2

3

10

5

9a 9b

9a 9b

Turns Ratio Measurement

Range

1.0 … 100’000

Accuracy

0.05% 

2293 BASIC SPECIFICATIONS

Complete technical specifications in the WA 2293 datasheet available at www.haefely.com

Resistance Measurement

Max. Measuring Current DC

32A (user selectable)

Max. Charging Voltage DC

100V

Range

0.1 μΩ … 300 kΩ

Accuracy

0.1% ± 0.5 µΩ

STANDARD PACKAGE

EXTENSIONS

WA 2293

3490068

Measuring Bridge (Portable and 
rack mounted version)

WA 2293

Software Add-ons

3-phase transformer turns ratio measurement

2293/SKTTR

Arbitrary phase shift (2293/SKTTR needed)

2293/SKAP

Heat rise temperature measurement

2293/SKTR

Magnetic balance measurement

2293/SKMB

Tap changer dynamic resistance measurement

22937/SKTC

Short circuit impedance measurement

2293/SKSC

Extended Warranty

2 years

WA 2293

3 years

WA 2823

Including

 

Winding resistance measurement

 

Demagnetization measurement

 

Heat run - Cooling curve measurement

 

8 measuring cables of 10 m length equipped 

with Kelvin probes

 

Cable bag

 

Test certificate

 

Instruction manual

1

2

3

Measurement Cables & Clamps

Extension cable 10 m high voltage side
Extension cable 10 m low voltage side

2293/10HV
2293/10LV

Additional measuring cables (HV & LV, 8 cables), 3 m length

2293/MK3

Tap changer control cable, allows remote tap changer control from measuring 

device and automate test sequences

2293/TAP

Extension clamps to increase the maximum openning distance of the standard 

clamps

ExtClamp

Temperature Sensors

Temperature extension box to connect up to 8 additional temperature sensors 

(max. 3 extension boxes per device)

2293/TEMPEXT

Temperature probe for liquids

2293/TEMP1

Temperature probe magnetic

2293/TEMP2

Laser infrared contactless thermo/hygrometer

TEMP

Provisions

Interlock provision

2293/IT

ACCESSORIES

4

9a

5

6

7

8

9b

10

14

15

Winding Resistance

TTR Turns Ratio

Heat Run Test

Demagnetize

Cap & Tan (Diss. Factor)

Short Circuit Impedance

FRA Frequency Response

RVM Water Content 

Excitation Current

W

A 2293

MIDAS micr

o

 2283

FRA 5311

RVM 5462a

Содержание WA 2293

Страница 1: ...Designed by WA 2293 Automatic Transformer Winding Analyser Leaflet ...

Страница 2: ...sistance turns ratio arbitrary phase vector group check demagnetization dynamic resistance short circuit impedance magnetic balance and heat run test heat rise and cooling curve Once connected can perform all tests in all phases on both windings More compact and lightweight solution in comparison to traditional equipment with up to 100A test current Easy operation Fully automated twinding resistan...

Страница 3: ... transformers like phase shifting or arc furnace which don t follow the standard 30 phase steps can be easily measured DYNAMIC RESISTANCE ON TAP CHANGER Dynamic resistance measurement is a reliable check of the transformer tap changer Discontinuities or deviations between different taps are signs of tap changer fault SHORT CIRCUIT IMPEDANCE Changes in the short circuit impedance along transformer ...

Страница 4: ...n be turned off at any point of time to disconnect the device thereby guarenteeing complete safety Quick Connection System The twin lock connectors and the one time connection system help to reduce connecting time drastically TemperatureMeasurement Temperature probes inputs 6 included up to 30 with the 2293 TEMPEXT to monitor the test object temperature during resistance measurement or heat run te...

Страница 5: ...bitrary phase shifts or those that do not follow the 30 phase steps between the primary and secondary winding are common in special transformers like phase shifting rectifier furnace and traction transformers With the optional arbitrary phase shift software key 2293 SKAP the 2293 can measure turns and voltage ratio phase displacement and excitation current of these special type transformers The sp...

Страница 6: ...ithout any reconnection Test results are shown graphically for a better understanding Imbalances will be graphically noted including the involved phases Short circuit impedance is a routine test done to all transformers after manufacture and specified in the transformer nameplate Changes in the short circuit impedance along transformer life is normally an indication of mechanical damages The 2293 ...

Страница 7: ...vailable magnetic and liquids temperature probes 2293 TEMP2 2293 TEMP1 are easily connected to the transformer Probe configuration is done graphically oil radiator top radiator bottom ambient In addition pre configured tests according to ANSI and IEC standards are included calculating the transformer temperature in real time and informing when stabilization is reached For the cooling curve the 229...

Страница 8: ...2823 Including Winding resistance measurement Demagnetization measurement Heat run Cooling curve measurement 8 measuring cables of 10 m length equipped with Kelvin probes Cable bag Test certificate Instruction manual 1 2 3 Measurement Cables Clamps Extension cable 10 m high voltage side Extension cable 10 m low voltage side 2293 10HV 2293 10LV Additional measuring cables HV LV 8 cables 3 m length ...

Страница 9: ...G Birsstrasse 300 4052 Basel Switzerland 41 61 373 4111 sales haefely com www haefely com CHINA HAEFELY AG Representative Office 8 1 602 Fortune Street No 67 Chaoyang Road Beijing 100025 China 86 10 8578 8099 sales haefely com cn www haefely com INDIA HAEFELY India Service Office C o Pfiffner Instrument Transformers Pvt Ltd 176 178 2 Sarul Viholi Nashik 422 010 India 1 800 266 4052 toll free sales...

Отзывы: