The simultaneous winding magnetisation method (patented)

together with the integrated DC power-supply guarantees fast 

and reliable winding resistance measurements. The 7” touch 
screen full graphical interface guides the operator through the 
single test procedures.

Independent currents can be selected for each winding, which 
guarantees reliable results even in transformers with large 
differences between windings.

WINDING RESISTANCE

With one optional temperature probe (available for liquids and 
magnetic), results can be automatically referenced to any target 
temperature (for example 75°).

The AC power supply integrated in the 2293 allows full 

automatic measurement of turns and voltage ratio, ratio 
deviation, phase displacement and excitation current of 

transformers.

Arbitrary phase shifts or those that do not follow the 30° 

phase steps between the primary and secondary winding 
are common in special transformers like phase shifting, 
rectifier / furnace and traction transformers.

With the optional arbitrary phase shift software key (2293/
SKAP), the 2293 can measure turns and voltage ratio, phase 
displacement and excitation current of these special type 
transformers.

The specially developed algorithmic included in 

 

compensated mode reduces the influence of leakage flux 
while using low voltage, giving results much closer to the 
nominal ratio.

The included type detection feature works as a nameplate 

guesser. It helps the user to determine the correct 

transformer configuration by showing the possible types 

and eliminating the wrong vector groups during the 
automatic detection process.

TURNS RATIO

ARBITRARY PHASE SHIFT

VECTOR GROUP DETECTION

With Simultaneous Winding 

Magnetization Test a complete 

transformer in a fraction of time!

8

9

Содержание WA 2293

Страница 1: ...Designed by WA 2293 Automatic Transformer Winding Analyser Leaflet ...

Страница 2: ...sistance turns ratio arbitrary phase vector group check demagnetization dynamic resistance short circuit impedance magnetic balance and heat run test heat rise and cooling curve Once connected can perform all tests in all phases on both windings More compact and lightweight solution in comparison to traditional equipment with up to 100A test current Easy operation Fully automated twinding resistan...

Страница 3: ... transformers like phase shifting or arc furnace which don t follow the standard 30 phase steps can be easily measured DYNAMIC RESISTANCE ON TAP CHANGER Dynamic resistance measurement is a reliable check of the transformer tap changer Discontinuities or deviations between different taps are signs of tap changer fault SHORT CIRCUIT IMPEDANCE Changes in the short circuit impedance along transformer ...

Страница 4: ...n be turned off at any point of time to disconnect the device thereby guarenteeing complete safety Quick Connection System The twin lock connectors and the one time connection system help to reduce connecting time drastically TemperatureMeasurement Temperature probes inputs 6 included up to 30 with the 2293 TEMPEXT to monitor the test object temperature during resistance measurement or heat run te...

Страница 5: ...bitrary phase shifts or those that do not follow the 30 phase steps between the primary and secondary winding are common in special transformers like phase shifting rectifier furnace and traction transformers With the optional arbitrary phase shift software key 2293 SKAP the 2293 can measure turns and voltage ratio phase displacement and excitation current of these special type transformers The sp...

Страница 6: ...ithout any reconnection Test results are shown graphically for a better understanding Imbalances will be graphically noted including the involved phases Short circuit impedance is a routine test done to all transformers after manufacture and specified in the transformer nameplate Changes in the short circuit impedance along transformer life is normally an indication of mechanical damages The 2293 ...

Страница 7: ...vailable magnetic and liquids temperature probes 2293 TEMP2 2293 TEMP1 are easily connected to the transformer Probe configuration is done graphically oil radiator top radiator bottom ambient In addition pre configured tests according to ANSI and IEC standards are included calculating the transformer temperature in real time and informing when stabilization is reached For the cooling curve the 229...

Страница 8: ...2823 Including Winding resistance measurement Demagnetization measurement Heat run Cooling curve measurement 8 measuring cables of 10 m length equipped with Kelvin probes Cable bag Test certificate Instruction manual 1 2 3 Measurement Cables Clamps Extension cable 10 m high voltage side Extension cable 10 m low voltage side 2293 10HV 2293 10LV Additional measuring cables HV LV 8 cables 3 m length ...

Страница 9: ...G Birsstrasse 300 4052 Basel Switzerland 41 61 373 4111 sales haefely com www haefely com CHINA HAEFELY AG Representative Office 8 1 602 Fortune Street No 67 Chaoyang Road Beijing 100025 China 86 10 8578 8099 sales haefely com cn www haefely com INDIA HAEFELY India Service Office C o Pfiffner Instrument Transformers Pvt Ltd 176 178 2 Sarul Viholi Nashik 422 010 India 1 800 266 4052 toll free sales...

Отзывы: