Safety Instructions 

 

The  installation  of  the  working  area  has  to 
correspond  to  the  relevant  regulations.  Set  up 
the unit in such a way, that the louvers are not 
covered and the extracted air can escape well. 

 

 

To avoid the risk of an electric shock, this device 
might only be connected to a power supply with 
protective conductor. 

 

 

If  you  pull  the  power  plug,  it  will  stop  the 
connection  to  the  mains  power  supply.  Set  up 
the  unit  so  that  the  power  plug  is  always 
accessible.  The  power  switch  should  also 
always be easily accessible. 

 

 

Only  switch  on  the  unit  if  the  handpiece  rests 
secured in the handpiece holder, or if you hold it 
safely in your hand. 

 

 

Prevent the permeation of liquids into the control 
unit.  The  electronic  elements  could  be 
damaged. Clean the outside of the box only with 
a  damped  cloth.  Be  sure  you  unplug  the  unit 
before. 

 

 

Only  when  pulling  the  mains  cable,  you  can 
ensure  that  the  device  will  be  completely 
disconnected  from  mains.  Check  the  mains 
cable regularly for damages, and in case of such 
let it change or repair by an authorized service 
center. 

 

Содержание HP-S2

Страница 1: ...Article 0592 FB 04 448 Rev 1 Date 28 11 2023 Manual HP S Automatic...

Страница 2: ...11 Startup Procedure 12 Application 13 Work Steps 13 Work Positioning 14 Spray Liquid 16 Insert Bur 17 Adjusting the Speed 17 Memory Buttons 17 Spray Function 17 Drying Function Tool Change 18 Foot S...

Страница 3: ...t Keep it somewhere safe If you give this product to someone else please include this document as it includes important information on how to use the product correctly Short description of functions T...

Страница 4: ...at the power plug is always accessible The power switch should also always be easily accessible Only switch on the unit if the handpiece rests secured in the handpiece holder or if you hold it safely...

Страница 5: ...a face mask conforming to EN 14683 type IIR or EN 149 FFP 2 must also be worn Ensure that the patient s foot and the handpiece are held firmly in place during the work To prevent injury work with extr...

Страница 6: ...ol sits firmly in the chuck do not work with tools which have an oily shaft are worn are bent Before using the equipment assure that the tool can be pushed far enough into the chuck test this with a d...

Страница 7: ...rry out any repairs modifications or maintenance work yourself This is only to be accomplished by an authorized specialist The mains cable may also only be changed by the manufacturer or an authorized...

Страница 8: ...leaning and user maintenance shall not be made by children without supervision This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities...

Страница 9: ...here to the cleaning and disinfection instructions provided below After every treatment please carry out these steps Remove the rotating tool e g bur first To do so pay attention to the instructions o...

Страница 10: ...F ON spray 3 decrease speed 4 increase speed 5 changeover switch for clockwise or anticlockwise operation 6 LED is ON during reverse rotation 7 memory button for rotation speed M1 M2 8 Start Stop butt...

Страница 11: ...or can be used as a portable unit e g in a carry case It is suitable for the following scopes foot care milling trimming and polishing works manicure grinding milling and polishing works The devise is...

Страница 12: ...oor Image Example of positioning of foot care unit in treatment room Image Bird s eye view of work area If you have a foot switch insert its plug into the port on the right of the device which display...

Страница 13: ...for clockwise use The rotation direction is irrelevant for diamond cutters and high grade corundum sanders in terms of efficiency Working anti clockwise can be beneficial if for example the dust obscu...

Страница 14: ...Application Work Positioning The following images are examples of how to work on various parts of the foot Always make sure that the foot is firmly gripped and that you can work freely and without str...

Страница 15: ...15 Application...

Страница 16: ...the housing Switch on the power switch in the rear of the unit Never use tap water Danger of calcification Also do not use explosive or combustible liquids e g alcohol Note Never refill the tank dire...

Страница 17: ...Frequently used speed levels can be saved Therefore three memory buttons are available At first choose your speed level and then save it by pushing button 7 m1 for 4 seconds To recall the above speed...

Страница 18: ...his function can also be used to change your tools while the handpiece is not running Foot Switch Connecting with control unit Only use the original foot switch art 0970 to avoid damages Insert the pl...

Страница 19: ...m Push the new washer in the top Please pay attention to the way it was installed Screw the top onto the handpiece tip Filter Even smallest parts of dirt could block the nozzle which sits in the top A...

Страница 20: ...of the whole spray system Parts of dirt are rinsed into the tank Do not use this liquid again Clean the tank immediately after realizing a blockage in the nozzle Otherwise the dirt particles might sti...

Страница 21: ...disinfection liquids This extraneous rost affects internal parts of the handpiece in form of rust bloom and causes pitting Therefore when you not working with the handpiece always remove the bur tool...

Страница 22: ...d on at the side of the unit Foot switch is used constantly or faulty Pull out the socket of the foot switch to see if this is the cause Pull out the mains plug to reset the device After lengthy use u...

Страница 23: ...N EN ISO 1797 1 Operating Time The device is designed for extended usage Ambient Conditions The device is intended for use in dry closed rooms Operation Temp 10 C to 26 C Rel humidity 25 to 75 not con...

Страница 24: ...rderly disposal of your unit please contact your distributor in your country Safety Check A safety check must be done in compliance with the regulations of the country where the device is used The ins...

Страница 25: ...s the lower and upper temperature limit air pressure permissible range air humidity permissible range Keep dry alternating current direct current safety fuse type B applied part socket foot switch dat...

Страница 26: ......

Страница 27: ......

Страница 28: ...hadewe GmbH Grambartstra e 10 30165 Hannover Germany info hadewe de www hadewe de...

Отзывы: