Application 

Work Steps 

In the following section  the order in 
which  you  should  use  the  device  is 
described. 

Additionally, 

the 

individual  steps  will  be  explained  in 
detail.  Read  the  complete  manual 
before use. 
 
After 

you 

have 

clamped 

the 

instrument, press the standby button 
(9) to deactivate the standby mode. 
Use the buttons (3) and (4) to select 
a  rotation  speed.  Manufacturers 
often  provide  recommendations  for 
optimal rotation speeds. However, it 
is  important  that  you  never  exceed 
the 

maximum 

recommended 

rotation 

speed. 

To 

start 

the 

handpiece  motor,  press  the  button 
(8). 
 
You  can  now  choose  a  rotation 
direction  using  the  button  (5).  The 
most  commonly  used  direction  is 
clockwise.  Most  milling  instrument 
(steel instruments with steel cutters) 
are optimized for clockwise use. The 
rotation  direction  is  irrelevant  for 
diamond  cutters  and  high-grade 
corundum  sanders  in  terms  of 
efficiency.  Working  anti-clockwise 
can be beneficial if, for example, the 
dust  obscures  your  field  of  vision 
when working clockwise. 
 
Now,  you  can  turn  on  the  spray  by 
pushing  button  (2).  By  using  the 
adjusting  knob  (1),  you  can  set  the 
amount of the spray liquid. 
 
After setting the speed and the spray 
amount, you can start with working. 
If you want to take a break or finish 

the job, press the standby button (9). 
The handpiece motor and spray will 
turn off. The handpiece can now be 
placed in its holder on the right of the 
unit.  Alternatively,  you  can  switch 
the  device  to  standby  by  pressing 
and  hold  the  button  on  the  foot 
switch. 
 
We recommend you disconnect the 
device from the mains power supply 
if is not going to be used for a while. 
This will save electricity. The mains 
plug must also be removed when  it 
comes to retiring the device. 

Содержание HP-S2

Страница 1: ...Article 0592 FB 04 448 Rev 1 Date 28 11 2023 Manual HP S Automatic...

Страница 2: ...11 Startup Procedure 12 Application 13 Work Steps 13 Work Positioning 14 Spray Liquid 16 Insert Bur 17 Adjusting the Speed 17 Memory Buttons 17 Spray Function 17 Drying Function Tool Change 18 Foot S...

Страница 3: ...t Keep it somewhere safe If you give this product to someone else please include this document as it includes important information on how to use the product correctly Short description of functions T...

Страница 4: ...at the power plug is always accessible The power switch should also always be easily accessible Only switch on the unit if the handpiece rests secured in the handpiece holder or if you hold it safely...

Страница 5: ...a face mask conforming to EN 14683 type IIR or EN 149 FFP 2 must also be worn Ensure that the patient s foot and the handpiece are held firmly in place during the work To prevent injury work with extr...

Страница 6: ...ol sits firmly in the chuck do not work with tools which have an oily shaft are worn are bent Before using the equipment assure that the tool can be pushed far enough into the chuck test this with a d...

Страница 7: ...rry out any repairs modifications or maintenance work yourself This is only to be accomplished by an authorized specialist The mains cable may also only be changed by the manufacturer or an authorized...

Страница 8: ...leaning and user maintenance shall not be made by children without supervision This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities...

Страница 9: ...here to the cleaning and disinfection instructions provided below After every treatment please carry out these steps Remove the rotating tool e g bur first To do so pay attention to the instructions o...

Страница 10: ...F ON spray 3 decrease speed 4 increase speed 5 changeover switch for clockwise or anticlockwise operation 6 LED is ON during reverse rotation 7 memory button for rotation speed M1 M2 8 Start Stop butt...

Страница 11: ...or can be used as a portable unit e g in a carry case It is suitable for the following scopes foot care milling trimming and polishing works manicure grinding milling and polishing works The devise is...

Страница 12: ...oor Image Example of positioning of foot care unit in treatment room Image Bird s eye view of work area If you have a foot switch insert its plug into the port on the right of the device which display...

Страница 13: ...for clockwise use The rotation direction is irrelevant for diamond cutters and high grade corundum sanders in terms of efficiency Working anti clockwise can be beneficial if for example the dust obscu...

Страница 14: ...Application Work Positioning The following images are examples of how to work on various parts of the foot Always make sure that the foot is firmly gripped and that you can work freely and without str...

Страница 15: ...15 Application...

Страница 16: ...the housing Switch on the power switch in the rear of the unit Never use tap water Danger of calcification Also do not use explosive or combustible liquids e g alcohol Note Never refill the tank dire...

Страница 17: ...Frequently used speed levels can be saved Therefore three memory buttons are available At first choose your speed level and then save it by pushing button 7 m1 for 4 seconds To recall the above speed...

Страница 18: ...his function can also be used to change your tools while the handpiece is not running Foot Switch Connecting with control unit Only use the original foot switch art 0970 to avoid damages Insert the pl...

Страница 19: ...m Push the new washer in the top Please pay attention to the way it was installed Screw the top onto the handpiece tip Filter Even smallest parts of dirt could block the nozzle which sits in the top A...

Страница 20: ...of the whole spray system Parts of dirt are rinsed into the tank Do not use this liquid again Clean the tank immediately after realizing a blockage in the nozzle Otherwise the dirt particles might sti...

Страница 21: ...disinfection liquids This extraneous rost affects internal parts of the handpiece in form of rust bloom and causes pitting Therefore when you not working with the handpiece always remove the bur tool...

Страница 22: ...d on at the side of the unit Foot switch is used constantly or faulty Pull out the socket of the foot switch to see if this is the cause Pull out the mains plug to reset the device After lengthy use u...

Страница 23: ...N EN ISO 1797 1 Operating Time The device is designed for extended usage Ambient Conditions The device is intended for use in dry closed rooms Operation Temp 10 C to 26 C Rel humidity 25 to 75 not con...

Страница 24: ...rderly disposal of your unit please contact your distributor in your country Safety Check A safety check must be done in compliance with the regulations of the country where the device is used The ins...

Страница 25: ...s the lower and upper temperature limit air pressure permissible range air humidity permissible range Keep dry alternating current direct current safety fuse type B applied part socket foot switch dat...

Страница 26: ......

Страница 27: ......

Страница 28: ...hadewe GmbH Grambartstra e 10 30165 Hannover Germany info hadewe de www hadewe de...

Отзывы: