5.52.420.00.01.09
17
NOTICE!
The limit switch function will only work if the movement direction of the load (lifting - lowering) corresponds
to the push buttons of the control switch.
12
Maintenance
12.1
General
All monitoring, servicing and maintenance operations are to ensure correct functioning of the equipment;
they must be effected with utmost care.
Only
“qualified persons” may do this work.
Servicing and maintenance work must only be done when the hoist is not loaded.
Records must be kept of all test results and measures taken.
12.2
Monitoring
The monitoring and servicing intervals stated are valid for operation under normal conditions and single-shift
operation. In case of severe operating conditions (e.g. frequent operation with full load) or special
environmental conditions (e.g., heat, dust, etc.), the intervals must be shortened correspondingly
12.3
Replacing the load chain
VORSICHT!
If there is any visible damage and when the conditions for replacement are reached (i.e. one or several
dimensions in the table have been reached, there is corrosion or elongation), the chain must be replaced.
When replacing the chain, also check the chain wheels.
Procedure:
Only insert new chains in an unloaded state.
Remove chain from its fastening at the end and attach a chain link which is open at the side.
A chain link which is open at the side, can easily be
produced by grinding out a small piece. The opening
must have the same thickness as the chain link.
Illustration 12
Hang a new original chain (same size and oiled) in the side opened chain link and insert it.
NOTICE!
The weld seam of the chain must be on the outside.
Illustration 13
Make sure the chain is not installed twisted.
Make sure the chain links are aligned in one direction.
Assemble the chain to the end fastening.
Running of the chain into the chain container:
Always run chains into the chain container by using the motor.
CAUTION!
Fill in the chain always motor driven.
Never run the chain in by hand, as there is a risk of knotting which can cause malfunctions and damage to
the device.