3.
Enable or disable the data logging mode that is shown on the display. Refer to the table that
follows for data logging mode descriptions.
Option
Description
EXTENDED POWER
MODE
Uses the least amount of power. When enabled, a reading is recorded for each
enabled input channel each time the logging interval ends (e.g., 1 minute or
5 minutes).
POWER SAVE
Automatically selected when the instrument thinks a battery is the power source.
When enabled, a reading for each enabled input channel is collected once per
minute. Then, the average reading for each channel is recorded each time the
logging interval ends.
CONTINUOUS
When enabled, a reading for each enabled input channel is collected once per
second. Then, the average reading for each channel is recorded each time the
logging interval ends.
4.
Select SET MEMORY MODE, then select an option.
Option Description
SLATE
When the memory is full, no more readings are recorded to the data log and the program is
completed (stopped).
WRAP
When the memory is full, the oldest reading is discarded from the data log each time a new reading
is recorded.
5.
Select the input channels to be recorded to the data log.
a.
Select SELECT INPUTS.
b.
Select one of the input channels shown.
c.
Push
CHANGE CHOICE
until Logged shows, the push
ACCEPT
.
d.
Select the logging interval for the input channel, then push
ACCEPT
. Refer to
e.
Enter more applicable settings for the input channel if applicable. Refer to
.
f.
again to record more input channels to the data log.
Table 16 Logging interval and days recorded – one input channel
Logging interval
128 kB RAM
512 kB RAM
Logging interval
128 kB RAM
512 kB RAM
Minutes
Days recorded (maximum)
Minutes
Days recorded (maximum)
1
12
80
12
144
963
2
24
160
15
180
1204
3
36
240
20
240
1606
5
60
401
30
360
2409
6
72
481
60
720
4818
10
120
803
Table 17 Additional input channel settings
Channel
Options
PROCESS TEMPERATURE
Logging interval, temperature units
Note: The temperature units can only be changed in this menu.
RAINFALL
Logging interval, rainfall units (inches or cm)
LEVEL/FLOW
Logging interval, level units, flow units