47
Section 8
Part Lists
8.1 Instrument configurations
8.2 Spare parts
What follows is a listing of materials you may require to maintain your instrument. Be sure to
mention the model number and item description when ordering.
For information on sensor spare parts and recharge kits, please refer to the accompanying
Sensor Manual
.
Part N°
Description
3650Ex/111
Substance measured: Oxygen, RS232 (serial) output: requires part no. 29122,
Special sensor: 31120E or GA2800 ATEX, Measurement units: ppm/ppb or ppm.
3650Ex/112
Substance measured: Oxygen, RS232 (serial) output: requires part no. 29122,
Special sensor: 31120E or GA2800 ATEX, Measurement units: %/ppm or %.
3650Ex/113
Substance measured: Oxygen, RS232 (serial) output: requires part no. 29122,
Special sensor: 31120E or GA2800 ATEX, Measurement units: ppm liquid phase, % gas
phase.
3650Ex/114
Substance measured: Oxygen, RS232 (serial) output: requires part no. 29122,
Special sensor: 31120E or GA2800 ATEX, Measurement units: kPa/Pa.
3650Ex/115
Substance measured: Oxygen, RS232 (serial) output: requires part no. 29122,
Special sensor: 31120E or GA2800 ATEX, Measurement units: bar/mbar.
3650Ex/211
Substance measured: Hydrogen, RS232 (serial) output: requires part no. 29122,
Special sensor: 31230E, Measurement units: ppm/ppb or ppm.
3650Ex/212
Substance measured: Hydrogen, RS232 (serial) output: requires part no. 29122,
Special sensor: 31230E, Measurement units: %/ppm or %.
Part N°
Description
32301
Electrochemical sensor cleaning and regeneration unit
32511.03
3 meter cable to connect 3650Ex instrument to interface box. Supplied with 2
connectors
32538.02
2 meter RS232 cable, to connect the interface box (29122) to a computer for the
3650Ex. Supplied with 2 female 9D connectors
32689
Windows software (WinLog97) for 3650Ex in English, French, German, or Spanish
32813
Rubber sealing gaskets for flow cell tubing adapters 32051 & 32051A. 6mm/¼" inside
diameter. 5 pcs
32814
Rubber sealing gaskets for flow cell tubing adapters 32051 & 32051A. 8 mm inside
diameter. 5 pcs
32960
3.6 V primary lithium non-rechargeable battery for 3650Ex
29122.X
PC Interface box, plus cables (32511, 32538) for 3650Ex. X: A=95-130VAC;
B=207-253VAC
31120E.01
EC Sensor, Substance measured: Oxygen, Sensing head material: Stainless Steel,
Guard ring: Silver, Maximum pressure: 50 bar, O-Ring: EPDM, Intrinsically safe
31230E.11
EC Sensor, Substance measured: Hydrogen, Sensing head material: Stainless Steel,
Guard ring: Platinum, Maximum pressure: 100 bar, O-Ring: Viton, Intrinsically safe
32007E.110
Flow chamber in stainless steel (316) with 6 mm fittings for use with 3650Ex. Supplied
with Viton O-rings
32007E.111
Flow chamber in stainless steel (316) with ¼" fittings for use with 3650Ex. Supplied with
Viton O-rings
32513E.04
4 meter sensor cable for 31XX0E and 3650Ex. Supplied with attached connectors
32809.MM
6x4mm plastic tubing (per meter). MM=specify total length
GA280E-SVS
GA2800 oxygen sensor, ATEX, stainless steel, viton o-rings, cap with grille
GA280E-SKS
GA2800 oxygen sensor, ATEX, stainless steel, kalrez o-rings, cap with grille
GA280E-HVS
GA2800 oxygen sensor, ATEX, hastelloy, viton o-rings, cap without grille
GA280E-HKS
GA2800 oxygen sensor, ATEX, hastelloy, kalrez o-rings, cap without grille