DOC272.53.80033

15

Parts

Description

Quantity

Catalog Number

IntelliCAL ORP/Redox gel-filled 
electrode, standard, with 1 m cable

1

MTC10101

IntelliCAL ORP/Redox gel-filled 
electrode, standard, with 3 m cable

1

MTC10103

IntelliCAL ORP/Redox gel-filled 
electrode, rugged, with 5 m cable

1

MTC10105

IntelliCAL ORP/Redox gel-filled 
electrode, rugged, with 10 m cable

1

MTC10110

IntelliCAL ORP/Redox gel-filled 
electrode, rugged, with 15 m cable

1

MTC10115

IntelliCAL ORP/Redox gel-filled 
electrode, rugged, with 30 m cable

1

MTC10130

Accessories

Description

Quantity

Catalog Number

Standard probe accessories

Citizen PD-24 USB handy printer, 
120-220 VAC

1

2960100

Color coded probe clips (5 color coded 
sets)

10/pkg

5818400

Electrode storage cap

5/pkg

5857305

Electrode storage cap lid

1

5829800

Field kit (Includes glove kit, and 5 120 
mL sample cups)

1

5825800

Glove kit only for HQd meters

1

5828700

IntelliCAL probe stand (for standard 
probes)

1

8506600

Meter stand

1

8506600

Printer paper for PD-24, thermal

5/pk

5836000

Probe holder for HQd meter (IntelliCAL 
standard models only)

1

5829400

Standard probe holder (use with 
protective glove)

1

5829400

USB and AC power adapters for HQd 
meters (included w/HQ40d)

1

5826300

USB/DC adapter for HQd meters (must 
have 5826300, inc w/HQ40d)

1

5813400

USB keyboard for HQd meters (must 
have 5813400 and 5826300)

1

LZV582

Rugged probe accessories

Electrode depth marker (rugged cable 
markers)

5/pk

5828610

Rugged field case for 2 probes with up 
to 5 m cables (10 m total). Includes: 
Empty case and insert for meter and 
probe storage, (4) containers for sample 
collection

1

8505500

Rugged field case for three probes with 
up to 5 m cables (15 m total). Includes 
same accessories as case 8505500.

1

8505501

Содержание MTC10101

Страница 1: ...EC European electrical equipment users must now return old or end of life equipment to the Producer for disposal at no charge to the user Note For return for recycling please contact the equipment pr...

Страница 2: ...int free cloth 4 If the electrode will not be used immediately fill the storage cap halfway with Hach Electrode Storage Solution or 3M KCl and install the cap 5 Install the shroud and locking ring and...

Страница 3: ...be must have the correct service life time stamp Set the date and time in the meter before attaching the probe It is not necessary to recalibrate when moving a probe from one HQd meter to another if t...

Страница 4: ...er blot dry and place it in the standard solution Make sure that the sample level is above the reference junction 5 Push Read Stir gently The display will show Stabilizing and a progress bar as the pr...

Страница 5: ...estion mark until the electrode is recalibrated Recalibrate the electrode to correct the status indicator Calibration on page 3 Measurement Measurement notes Data is stored automatically in the data l...

Страница 6: ...nect the electrode to the meter 3 Rinse the electrode with the sample and place the electrode in fresh sample 4 Push Read The display will show Stabilizing and a progress bar as the probe stabilizes i...

Страница 7: ...ng many substances in solution A redox titration consists of adding to an unknown sample small increments of a titrant that converts the unknown to a different oxidation state After each addition of t...

Страница 8: ...ng the potential after each addition Near the end point when large potential changes appear add increments of 0 1 0 2 mL Continue the titration 3 4 mL past the end point 5 Plot the electrode potential...

Страница 9: ...d 1 Unscrew the locking ring and slide the shroud and locking ring off the probe 2 Slide the shroud and locking ring off the probe To install the shroud 1 Place the locking ring on the probe body with...

Страница 10: ...ings which cannot be changed A saved method can be used instead of repeatedly adjusting individual settings Changes made to a user defined method are automatically saved with the existing name Multipl...

Страница 11: ...V The measurement limits can be set to match the acceptable values for the sample When the measurement is above the upper limit setting or below the lower limit setting the meter will show an Out of l...

Страница 12: ...200 0 mV Custom standard value Custom standards are characterized at 25 C Table 4 Calibration options settings Settings Option Description Table 5 Check standard options settings Settings Options Desc...

Страница 13: ...sponse time Contaminated reference junctions Rinse reference junction with deionized water thoroughly shake the electrode downward to remove any air bubbles and soak in 3 0 M KCl storage solution for...

Страница 14: ...ts Check standard value is outside of limits set in the current method Verify that the standard is within the limits of the current method Create a new method that expands the acceptable limits Measur...

Страница 15: ...storage cap lid 1 5829800 Field kit Includes glove kit and 5 120 mL sample cups 1 5825800 Glove kit only for HQd meters 1 5828700 IntelliCAL probe stand for standard probes 1 8506600 Meter stand 1 850...

Страница 16: ...insert for meter and two probe storage cavities space for storage of HQd meter with protective glove 1 8505600 Rugged shroud kit 1 5825900 Consumables Electrode cleaning solution 500 mL 2965249 Electr...

Отзывы: