11
Tank wall mount kit, LZX414.00.71000 and LZX414.00.72000
Attach the protective plate
1.
Attach the protective plate on the bottom jointed pipe as shown in
.
a.
Insert the flat head cap screws (M8 x 120 mm) through the protective plate and
the spacers.
b.
Hold both against the pipe and loosely tighten the pipe clamps using self-locking
M8 nuts and washers.
2.
Move the protective plate so that the sensor is suspended approximately 5 cm above
the bottom edge of the protective plate.
Important Note:
Align the protective plate so that it is vertical to the movement of the
rotating scraper and parallel to the axis of the joint. Make sure the spacers do not block the
probe LED and the probe is aligned with 2 feet towards the plate.
3.
Tighten the nuts.
Figure 12 Attach the protective plate
1
Flat head cap screw M8 x 120 mm
4
Spacers
2
Protective plate
5
Pipe clamp
3
Bottom jointed pipe
6
Self-locking hex nut M8