Setting Work and Tool Offsets
47
F7.8:
UMC Z-Axis Work Zero Offset Start
1.
Load the work probe into the spindle.
2.
Make sure that the B and C Axes are at the same work zero point set earlier.
(
G00 G90 G54 B0 C0
). Refer to the Set the B-Axis Work Offset and Set the C-Axis
Work Offset sections if these values are not correct.
3.
Set the X- and Y-Axis offsets using the standard WIPS templates as appropriate.
Refer to the WIPS manual for more information.
4.
Position the work probe tip approximately 0.25" (6 mm) above the Z-Axis zero
surface.
5.
Navigate to
[OFFSET]
Work
. Scroll to the work offset value used in the program (
G54
in this example).
6.
Press the
[RIGHT]
cursor arrow until you reach the
Probe Action
sub-menu.
7.
Type
11
, and then press
[ENTER]
to assign the
Single Surface
Probe Action
to the offset.
8.
Press
[PART ZERO SET]
to move to
VPS
.
9.
Select the Z Variable.
0.25"
(6 mm)