Procedure: 

 

The required value can be selected with the 

“Plus”

 or 

“Minus”

 buttons. 

 

The setting is saved by pressing the 

“OK”

 button. 

 

To exit the function, press the 

“On/Off”

 button.

 

9.1.9. Software version information 

Info Software

SW-Version: HSP-6-V5.03
test date: 2015-02-11

 

Procedure:

 

 

 

To exit the function, press the 

“On/Off”

 button.

 

 

9.1.10. 

Test setting

 

Heating in the test position is only permitted by specialists of various 
test laboratories!

 

In this menu, the partial load / nominal load is tested according to EN 14785 
standard. 

Procedure:

 

Use the "

Plus

" or "

Minus

" keys to enter the required code. 

The code is as follows: 

1854

 

Pressing the "

OK

" button saves the setting.

 

 

The test setting partial load or nominal load is then selected. 
Pressing the "

OK

" button activates the "

START

" of the respective test setting.

 

 

 
 
 
 
 

 

 

  

 

 

 

10.  Operating statuses: 

10.1. Start Zone 1-20 ( Start phase ) 

The start phase begins if: 

 

the current room temperature falls below the set target temperature by 1°C 

 

the stove is cooled down to a temperature below 70 C° 

 

During the “Start phase”, the burner tray is filled with a precisely defined amount of fuel and this fuel is ignited using 
an electric ignition. 

The whole “Start phase” can go through up to 20 zones. It finishes after reaching a precisely defined temperature at 
the “flame temperature sensor” and the control system puts the stove into “Heating mode”. 

The duration of the “Start phase” can therefore vary. 

If, during the start phase, no flame generation can be achieved or the required temperature at the “flame temperature 
sensor” cannot be reached, a switch-off process is initiated. 

Typ

 

Chimney draft at nominal heat output / partial load

 

HSP 1, HSP 2

 

11 / 7  Pa

 

HSP 6

 

11 / 5  Pa

 

HSP 8

 

11 / 6  Pa

 

 + -   

OK

" * "

Test setting

Code input

Содержание 0541808010000

Страница 1: ...8 PELLET STOVE Nameplate Aufstellungs und Bedienungsanleitung Pelletofen DE Fiche descritive Poele FR Schema tecnica strufa Camino IT Equipment sheet Fireplace GB Tshnicki podaci Kaminsku HR Podatkovni list Kaminsko SLO ...

Страница 2: ...8 8 2 Energy saving mode ACTUAL room temperature display 9 8 3 Button lock child safety device 9 9 Functions in the main menu 9 9 1 Main menu Select functions 9 9 1 1 Operating mode Week program Settings 10 9 1 2 Setting the time and date 11 9 1 3 Setting the language 11 9 1 4 Heating curve How it works 11 9 1 5 ECO mode 12 9 1 6 Network 12 9 1 7 Fill manually Optional only on HSP8 12 9 1 8 Contra...

Страница 3: ...stricted covered or shut off On stoves with an outdoor air connection the opening must not be shut or closed during operation Make children aware of these dangers and keep them away from the fireplace when it is in heating mode The combustion chamber door must only be opened for cleaning and maintenance purposes when in Off mode Otherwise this should always be kept closed The pellet stove may only...

Страница 4: ...e flue tube does not stick out into the open cross section of the chimney which would interfere with the flue gases rising and prevent the optimal cleaning of the chimney The use of wall lagging is recommended for the insertion into the chimney see Figure 3 Longer horizontal flue gas connections reduce the necessary flue draft All openings leading into the same chimney such as stove and chimney cl...

Страница 5: ... recommended to feed the cold air into the room from outside via a direct duct as this can lead to the build up of condensation In order to guarantee a sufficient supply of air the duct should not be longer than approx 3 m and not have too many bends If the duct leads outside it must end with a 90 bend facing down or a wind protection device see Figure 4 Figure 4 Wind protection of air supply duct...

Страница 6: ...iameter Identification DINplus ÖNorm M 7135 ENplus A1 7 2 Unsuitable fuels The use of lower quality or unauthorised fuel adversely affects the operation of your pellet stove and may lead to the lapse of the guarantee Burning wood pellets of a poor quality leads to cleaning intervals becoming shorter and more fuel being consumed Unauthorised fuels are for example wood chips straw maize firewood etc...

Страница 7: ... its mounting Close the combustion chamber door Fill the storage container with pellets Plug in mains cable Tip Only when using for the first time place approx 30 pellets in the burner This speeds up the ignition process 7 3 2 Operating console 7 3 2 1 Software version As soon as the mains plug is connected the software version appears on the display for approx 7 seconds e g Software HSP 6 V5 03 7...

Страница 8: ...ver until it reaches the necessary flame temperature and only then switches to the cooling operating status and then OFF During the first use odours may build up for a short time Please ensure that there is adequate ventilation in the installation room during this time and avoid inhaling directly General If the start phase could not be successfully completed i e no flame generation or the required...

Страница 9: ...activation Hold the Menu button down for approx 10 seconds until Button block activated no longer appears on the display 9 Functions in the main menu 9 1 Main menu Select functions OK language english heating curve 2 main menu oper mode date time Prerequisite Welcome page is displayed The Main menu page appears by pressing the OK button This menu is shown as a scroll down menu The following functi...

Страница 10: ...itch on time can now be set with the Plus or Minus buttons The switch off time on the respective week day can be programmed by pressing the right hand arrow button The required room temperature is selected by pressing the right hand arrow button again This procedure can be used to set 3 heating zones for each day with the respective room temperature Week program symbol active 28 C 26 C standby men...

Страница 11: ...t with the Plus or Minus buttons The setting is saved by pressing the OK button To exit the function press the On Off button 9 1 4 Heating curve How it works h003 OK 2 2 main menu heating curve set factor Setting range of the heating curve from 1 to 4 Factory setting 2 The value to be set is based on the size of the room being heated Guide values Room size 20m Value 1 Room 25m Value 2 Room 30m Val...

Страница 12: ...s given on the WLAN module operating instructions 9 1 7 Fill manually Optional only on HSP8 on screw conveyor off main menu Fill manually Procedure Place the cursor in the main menu on Fill manually Press OK button on the right to switch on The screw conveyor then turns thus feeding the pellets As soon as the pellets move into the burner via the chute the feed process is stopped by pressing the OK...

Страница 13: ... the START of the respective test setting 10 Operating statuses 10 1 Start Zone 1 20 Start phase The start phase begins if the current room temperature falls below the set target temperature by 1 C the stove is cooled down to a temperature below 70 C During the Start phase the burner tray is filled with a precisely defined amount of fuel and this fuel is ignited using an electric ignition The whol...

Страница 14: ...ECO mode Eco mode means continuous operation at a low output if the ACTUAL room temperature is higher than the set TARGET room temperature i e the stove does not switch off but continues to run on a smaller flame If the set TARGET room temperature is exceeded by more than 2 C in eco mode despite a small flame eco mode is automatically switched off and the stove switches to the Cooling down operati...

Страница 15: ...up battery so that data is retained during a power cut A distinction is made between a short power cut and a long power cut Short power cut The short cut lasts for less than about 30 seconds Once the electricity supply has been restored the stove continues its operation Long power cut The short cut lasts for more than about 30 seconds Once the electricity supply is restored the stove switches to t...

Страница 16: ...ctive G Pellet fuel has too low a calorific value A Clean burner B Clean burner fill pellet tank C Clean the intake on the screw conveyor housing with a vacuum cleaner Clean burner D Clean burner Ensure adequate combustion air E Flue gas temperature sensor defective contact service department F Screw motor defective contact service department G Clean burner switch to high quality pellet type F006 ...

Страница 17: ...calorific value E Downpipe screw conveyor blocked F Room too airtight required combustion air cannot flow into the room G Flame temperature sensor defective H Screw motor defective A Fill pellet tank B Position burner correctly C Check burner clean burner D Switch to high quality pellet type E Clean the intake on the screw conveyor housing with a vacuum cleaner F Ensure adequate combustion air Con...

Страница 18: ...seals seals of any kind handles invalidate a warranty Maintenance or cleaning not performed or performed inadequately a flue draft that is incorrectly set to the appliance or is insufficient or too high improper commissioning negligence and changes to the appliance also invalidate a warranty If any constructional change is made to the stove or if it is not used for the intended purpose any claim u...

Отзывы: