15
Figure 8b:
Removing the side wall
Figure 8c:
Removing the side wall
Undo the screws and remove both the covers of the
openings. Now you can clean the exposed insides of the
flue gas passes. (See Figure 8 d+e).
After completion of the cleaning make sure that
when putting back the covers, the seals are seated
in the right positions. It is essential to replace
defective seals.
Figure 8c:
Cleaning covers
Figure 8d: Cleaning covers open
8.7.
Cleaning the induced draught housing and fan
This housing is made accessible for cleaning by undoing
the 4 nuts shown in Figure 9. (See arrows).
Remove the induced draught motor by pulling it out.
Now clean the flue gas passes, the induced draught fan
and the flue tubes with a brush and an ash vacuum
cleaner.
Then reassemble the components in reverse order.
Make sure that the seal is seated in the right position
again. It is essential to replace defective seals.
Make sure of the electrical connections on the fan motor
and their correct positions.
Figure 9: Induced draught fan
1 =
Screw
2 = Blower motor
3 =
Seal
3
2
1
3x