Product number. 0618218019030
V09 G07
2
Nennwärmeleistung
Zugelassener Brennstoff:
Staub bez.auf 13% O
2:
28mg/Nm³
Wirkungsgrad: 81,7%
CO:0,10%
Prüf Nr. VKF: 11108
NOx: 93 mg/Nm³
HC: 44 mg/Nm³
8,0 kW
Holz, Holzbrikett nach -DIN 51731,
Prüfstellenkennziffer: 1625 / Prüf Nr. RRF-29 06 1188
Lesen und befolgen Sie die Bedieungsanleitung!
Mehrfachbelegung des Schornsteins ist zulässig
Herstellnummer:
JH 03 000085
Wärmeleistungsbereich:
4,7 - 9,2kW
HAAS + SOHN OFENTECHNIK GMBH
URSTEIN NORD 67 A-5412 PUCH
Kamineinsatz Bauart : EN 13229-W / Zeitbrandfeuerstätte
Typenbezeichnung:
Exquisit 182.18-AL
Description of the system for supplying the air needed for combustion:
The system for supplying the air needed for combustion in stove unit type 182.18_AL has three settings: the
primary air is adjusted by means of the air intake control(11) With the handle in position 2 (‘left’) the primary
air. I enters through the grate, and the primary air II enters through that area of the combustion chamber which
is to wards the front of the stove. With the handle in position 1 (‘middle’) the primary air I only enters via the
grate. The amount of secondary air is set at an optimum level for the unit to provide the necessary ventilation
to keep the window clean and to provide the necessary air for secondary combustion; it is permanently
adjusted for increased comfort. The pre-heated secondary air flows past the top end of the inspection window
(8).
Air intake control
Primary air I
Primary air II
Use:
"left" open
open
For use when it is heating up and after
fuel has been added
"middle"
shut
open
In normal operation
"right"
shut
shut
Only for keeping the embers glowing
Connection for providing the air needed for combustion:
In airtight buildings there can be reduction in the oxygen content of the room in which the stove is set up; it must
therefore be ensured that there is adequate ventilation. The stove unit type 182.18-AL therefore offers you the
possibility of drawing in the air needed for combustion from outside. The stove can then be operated without
having to depend on the air within the room. In order to do this the air from outside that is needed for
combustion is supplied by means of a flexible pipe attached to the socket for the pipe (18). It is possible for you
to change the position of the pipe socket to the left, right or rear of the stove unit.
The end of the pipe carrying
the air must be located in the open air, or in a well ventilated room situated within the building. Operation of the
stove unit in connection with an air conditioning and ventilation system is permitted. When installing the stove
unit in connection with an automatic air conditioning and ventilation system the end of the pipe supplying the air
must not be located in a room which is connected to this system.
Fuels
Amount of fuel
Primary air:
air intake control
Secondary air
(not adjustable)
Chopped
wood
Wood
briquettes:
2 to 3 pieces of
wood (approx. 2 to 2.5kg)
or 1 wood briquette (2kg)
For approximately 10 minutes: open
(handle to the left),
then operate with the handle in
the middle position
open
The amount of fuel and adjustment of the air intake control:
Lighting, and heating the appliance up: see sections 5.4, 5.5 and 5.6 in the instructions for use of the stove.
Use the gloves provided to protect you against the heat when operating the air intake control.
Before every addition of fuel, the air intake control is to be closed completely (handle setting ‘left’).
Tip for burning wood:
Every time the stove is lit leave the appliance in the ‘right’ position until the
fuel is burning well (around 10 minutes). (This time can vary somewhat depending on the amount of
draught and the pressures involved).When adding fuel shut the air intake as indicated.
Stove unit: Exquisit 182.18-AL:
RRF Essen
RRF-29 06 1188
Stove EN13240:
stove „Colmar“,
RRF-40 02 476