The Ofice Mill runs on single-phase power. It has a transformer in the control that con
-
nects to voltage that can range from 195V to 254V.
1. Measure voltage at the main circuit breaker and connect the main power cable to
the appropriate tap on the transformer (taps available are 195-213V, 214-225V,
and 226-254V).
2. The mill has a power cord with a L6-20P plug that can be plugged directly into
power using a L6-20R connector. This connector has 2 power pins and a ground
pin; the ground pin must be wired into the building’s ground system.
L1
L2
Single-Phase Connection
Line
Load
Connecting Air
CAUTION
Make sure all pressure is removed from the air line before
you connect or disconnect it. Pressurize the air line only
when it is connected to the machine.
1. Refer to the procedure given in the Installation section of the Service manual to
connect air to the Ofice Mill.
2. Set the incoming air pressure to between 75 and 150 psi. Set the air regulator on
the machine to 60 psi (0.4 mPa).
Spindle
30K, ISO20 Spindle Features
• 5HP (3.7 KW) peak power, 3HP (2.2KW) continuous duty spindle power.
• Spindle speed range of 0-30,000 rpm, ininitely variable.
• Precision (ABEC 7) angular contact bearings, grease lubricated.
• Automatic tool changing system, featuring ISO20 tooling, without drive slots.
ER16 collet chucks with precision collets are recommended.
• Rigid tapping standard for 30K spindle: limitations based upon horsepower and
absence of drive dogs.
• Spindle Orientation is included with the 30K spindle option and intended for use
with the Visual Quick Code Probing System. This Spindle Orientation option
should not be used for high accuracy indexing.