Mounting the access controller chassis 

Rack-mounting the access controller 

The WX6103 can be installed in an N68 cabinet of H3C or a standard 19-inch cabinet based on your 

actual requirement. The procedures for installing the WX6103 in these two types of cabinets are similar. 

The following describes how to install the WX6103 in an N68 cabinet. 

 

The N68 cabinet was shipped to your order with the mounting position for the WX6103 made ready and 

all the accessories outside the access controller chassis installed, except for the switch interface board 
cables. For how to install the N68 cabinet, see the 

N68 Cabinet Installation and Remodel Introduction

.  

Figure 14

 

Mount the access controller in an N68 cabinet 

Содержание WX6103

Страница 1: ...H3C WX6103 Access Controller Installation Guide Hangzhou H3C Technologies Co Ltd http www h3c com Document version T1 08040X 20101216 C 1 04...

Страница 2: ...gzhou H3C Technologies Co Ltd All other trademarks that may be mentioned in this manual are the property of their respective owners Notice The information in this document is subject to change without...

Страница 3: ...king with the WX6103 Conventions This section describes the conventions used in this documentation set GUI conventions Convention Description Button names are inside angle brackets For example click O...

Страница 4: ...available commands Software configuration Configuration examples Describe typical network scenarios and provide configuration examples and instructions Operations and maintenance Release notes Provid...

Страница 5: ...Documentation feedback You can e mail your comments about product documentation to info h3c com We appreciate your comments...

Страница 6: ...Appearance 1 Dimensions and weight 2 Power supply 2 Fan tray 4 Air filter optional 5 Main control boards 6 Main control board specifications 6 Main control board front panel 6 Provided interfaces 7 R...

Страница 7: ...talling a board 42 Removing and installing the fan tray 43 Removing the fan tray 43 Installing the fan tray 43 Installing the mounting brackets and cable management bracket 44 Attaching the cable mana...

Страница 8: ...by the access controller 63 BootWare program file 63 Application files 63 Configuration files 64 Approaches for software maintenance 64 BootWare menus 65 BootWare main menu 65 BootWare submenus 66 Upg...

Страница 9: ...er When you install two main control boards you can set them to work in one of the following modes Independent mode the two main control boards work independently increasing the service processing cap...

Страница 10: ...2 Figure 2 Rear panel of the WX6103...

Страница 11: ...Us while without interrupting ensuring the normal operation of the access controller check that the power switch is off before plugging a PSU and then power turn on the power switch Redundancy Support...

Страница 12: ...4 Figure 4 Front panel of the PSR650 D...

Страница 13: ...5 Figure 5 Fan structure...

Страница 14: ...l or remote configuration and management through dial up connection One console port with the transmission speed of 9600 bps to 115200 bps 9600 bps by default Supports local or remote configuration an...

Страница 15: ...7 Figure 8 Front panel of the EWPXM1WCMD0...

Страница 16: ...inking data is being transmitted received Console port The WX6103 provides an RS 232 asynchronous serial console port CON using an RJ 45 connector The console port can be connected to a computer for s...

Страница 17: ...press the reset button while the access controller is rebooting or accessing the CF card or USB device as this may damage the file system of the access controller LEDs on the main control board panel...

Страница 18: ...10 Figure 10 LEDs on the EWPX1WCMD0...

Страница 19: ...es See the chapter Specifications for transceivers and interface cables XFP transceiver module types See the chapter Specifications for transceivers and interface cables Switch interface board front p...

Страница 20: ...ex Supported optical fiber modules 1000BASE SX SFP 1000BASE LX SFP Functions Data exchange 10 GE interface module The switch interface board provides a one port or two port 10 GE interface module for...

Страница 21: ...13 Figure 12 LEDs on the switch interface board panel...

Страница 22: ...ty Clear the work area of possible hazards such as ungrounded power extension cables missing safety grounds and wet floors Locate the emergency power off switch in the room before installation Shut th...

Страница 23: ...t strap is well grounded CAUTION Check the resistance of the ESD preventive wrist strap for safety The resistance reading should be in the range of 1 to 10 megohm Mohm between human body and the groun...

Страница 24: ...nt room Substance Concentration limit particles cu m Dust particles 3 x 104 No visible dust on desk in three days NOTE Dust particle diameter 5 m In addition the equipment room should meet strict limi...

Страница 25: ...For adequate ventilation and ease of maintenance adhere to the following requirements The clearance between the cabinet and walls or other devices is at least 1 m 3 28 ft The headroom in the equipment...

Страница 26: ...6 Box end wrenches M6 Double box end wrenches 10 12 or double open end wrenches 10 12 Small tools Sharp nose pliers diagonal pliers vices hand held electric drills file handsaws crowbars rubber hammer...

Страница 27: ......

Страница 28: ...of cabinets are similar The following describes how to install the WX6103 in an N68 cabinet The N68 cabinet was shipped to your order with the mounting position for the WX6103 made ready and all the...

Страница 29: ...ting the grounding cable WARNING For the safety of operators and equipment securely ground the access controller Most cabinets are equipped with a grounding strip You can connect the grounding wire ye...

Страница 30: ...22 Figure 15 Connect the PGND cable...

Страница 31: ...23 Figure 16 Appearance of the PSR650 A...

Страница 32: ...nits of mm2 Follow these steps to connect the AC power cables for a DC PSU Step1 Set the power switch on all the DC PSUs to the OFF position Step2 Remove the terminal protection cover from the DC PSU...

Страница 33: ...ole cable The console cable is an 8 core cable with an RJ 45 connector at one end for the console port of the access controller and a DB 9 female connector at the other end for the 9 pin serial port o...

Страница 34: ...l D NOTE Tx Transmit data Rx Receive data BI Bidirectional data Table 20 RJ 45 MDI X pinouts 10Base T 100Base TX 1000Base TX Pin Signal Function Signal Function 1 Rx Receive data BIDB Bidirectional B...

Страница 35: ...in optical fiber communication systems Fiber connectors make removable optical connections possible This facilitates the testing and maintenance of the optical system and enhances the system flexibil...

Страница 36: ......

Страница 37: ...WX6103 on the cable management bracket at the left of the chassis and the AC or DC power cables at the front of the chassis Cabling for a cabinet mounted access controller If the access controller is...

Страница 38: ...f any sharp edges Make sure that metal cabling holes have smooth and rounded surfaces or furnished with an insulating bush Use the proper size cable ties instead of joined ties to bind cables Presentl...

Страница 39: ...screws or nuts fasten the screws or nuts and take measures to prevent them from getting loosened as shown in the following figure Figure 28 Cable fixing example 1 2 3 4 1 Flat washer 2 Flat washer 3 S...

Страница 40: ...e to avoid bodily injury or device damage due to improper connections After the installation check that the following items are correct Table 23 Checklist after installation Item Normal Abnormal Remar...

Страница 41: ...n environment To configure your access controller you need to set up a configuration environment by connecting a terminal a PC in this example to the console port of your access controller AC with a c...

Страница 42: ...ect a serial port from the Connect using drop down list as shown in Figure 31 Be sure to select the serial port to which the console cable is actually connected Figure 31 Select a port for local confi...

Страница 43: ...munication parameters NOTE To use the default settings click Restore Defaults Step5 After setting the serial port parameters click OK to enter the HyperTerminal window as shown in Figure 33 Figure 33...

Страница 44: ...he access controller verify the following items All cards are correctly installed All communication cables fibers power cables and grounding cables are correctly connected The power outlet voltage mat...

Страница 45: ...interface module in place 4 All the LEDs go into normal indication status For more information see the chapter Access controller overview The system LEDs on the main control board panel work normally...

Страница 46: ...Ware Validating Press Ctrl B to enter extended boot menu Starting to get the main application file cfa0 wx6103 bin The main application file is self decompressing Done The NP application file is self...

Страница 47: ...cess controller provides abundant command views For more information about the configuration commands and CLI see the H3C WX Series Access Controllers Configuration Guide and H3C WX Series Access Cont...

Страница 48: ...removed and installed This section uses an AC PSU as an example CAUTION The power supply units PSUs of the WX6103 access controller are hot swappable To avoid bodily injury do not touch any naked wir...

Страница 49: ...SU conforms to the power input Step2 With one hand holding the PSU handle and the other hand supporting the bottom of the PSU gently push it into the chassis along the slot until it is in good contact...

Страница 50: ...42 Removing a board Figure 36 Remove a board...

Страница 51: ...e fan tray CAUTION To prevent bodily injury do not touch any naked wires terminals and parts with a high voltage hazard warning sign When replacing the fan tray while the access controller is working...

Страница 52: ...d with the WX6103 access controller You need to assemble the cable management bracket and the mounting brackets together before installing them to the access controller chassis Attaching the cable man...

Страница 53: ...45 Installing the mounting brackets to the chassis Figure 39 Install the mounting brackets to the chassis...

Страница 54: ...ilter from the rear side along the guide rails as shown in callout 2 of Figure 40 Step3 Secure the air filter with captive screws as shown in callout 3 of Figure 40 Removing the air filter Follow thes...

Страница 55: ...are see the chapter Software maintenance through the BootWare menu The following approaches are available for upgrading application files Upgrading application files through the web interface Uploadin...

Страница 56: ...he PC to VLAN 1 By default all GE interfaces on the switch interface board belong to VLAN 1 Sysname interface GigabitEthernet0 0 1 Sysname GigabitEthernet0 0 1 undo port access vlan NOTE The access co...

Страница 57: ...rade Step1 After logging in to the web interface select Device Device Maintenance from the navigation tree to enter the page as shown in Figure 43 Figure 43 Software upgrade page Step2 Clirk Browse to...

Страница 58: ......

Страница 59: ...file to remote TFTP server Please wait TFTP 31762740 bytes sent in 52 second s File uploaded successfully CAUTION When you back up a file to the server this file will overwrite a file that has the sam...

Страница 60: ...troller You must make sure that it is available by yourself This section describes how to maintain the access controller software using the FTP client application that comes with Microsoft Windows XP...

Страница 61: ...vel of user guest to 3 manage level ftp put wx6103 bin wx6103 bin Download to the access controller 200 Port command okay 150 Opening BINARY mode data connection for wx6103 bin 226 Transfer complete f...

Страница 62: ...05 25 200 13 226 125 Using existing data connection 226 Closing data connection File transfer successful FTP 39709988 byte s received in 66 660 second s 595 00K byte s sec Use the put command to back...

Страница 63: ...any input error restart the loading process with correct inputs Input errors include A baud rate other than 9600 bps selected for BootWare loading using Xmodem An improper baud rate setting in HyperTe...

Страница 64: ...wer source is abnormal If a PSU does not work normally possible causes are as follows The power input is abnormal The PSU is overheated The PSU fan is abnormal Check the following items The power sour...

Страница 65: ...is in an abnormal condition The ALM LED lights up during board reset and should go off after the board is normally started If the ALM LED does not light up when the board is reset possibly there is n...

Страница 66: ...al transceiver modules Table 30 Technical specifications for GE optical transceiver modules Transceiver module Central wavelength Connector type Fiber specification Maximum transmission distance 50 12...

Страница 67: ...125 m single mode fiber 70 km 43 50 miles SFP GE LH70 SM1 530 CW 1530 nm LC 9 125 m single mode fiber 70 km 43 50 miles SFP GE LH70 SM1 550 CW 1550 nm LC 9 125 m single mode fiber 70 km 43 50 miles SF...

Страница 68: ...nts Ordering the access controller Table 31 Ordering information for the WX6103 access controller Description Quantity Remarks Access controller H3C WX6103 1 Required excluding the power supply PSR650...

Страница 69: ...310 nm SFP module long haul 1550 nm SFP module ultra long haul 1550 nm Connector type LC Maximum transmission distance 0 55 km 0 34 miles 10 km 6 21 miles 40 km 24 86 miles 40 km 24 86 miles 70 km 43...

Страница 70: ...es 40 km 24 86 miles 80 km 49 71 miles Central wavelength 850 nm 1310 nm 1550 nm 1550 nm Min 1 08 dBm 0 5 dBm 2 dBm 4 dBm Optical transmit power Max 7 3 dBm 8 2 dBm 1 dBm 0 dBm Receive sensitivity 7 5...

Страница 71: ...n Extended BootWare provides abundant man machine interaction functions It is used for interface initialization for application program and boot system upgrade Full BootWare refers to the combination...

Страница 72: ...ication file You can only download it using the BootWare menu Only one file of the same type M B or S can exist in the CF card For example if an application file of type M B exists in the CF card anot...

Страница 73: ...roller power on or reboot the console terminal connected with the access controller first displays the following information System start booting Then the following information appears Booting Normal...

Страница 74: ......

Страница 75: ...Main Menu Enter your choice 0 4 The following output is displayed on the EWPX1WCMD0 File CONTROL Note the operating device is cfa0 1 Display All File s 2 Set Application File type 3 Delete File 0 Exi...

Страница 76: ...vailable Nonvolatile Storage Devices set the storage device for read and write operations and set the default boot device in the storage device operation submenu Select 9 in the BootWare main menu to...

Страница 77: ...ps press ENTER when ready The serial interface baud rate of the access controller has been changed to 1 15 200 bps while that of the terminal is still 9 600 bps the access controller and the terminal...

Страница 78: ...en press Enter in the serial interface submenu The system prompts the current baud rate and returns to the parent menu The current baudrate is 115200 bps BAUDRATE SET Note indicates the current baudra...

Страница 79: ...meter 0 Exit To Main Menu Enter your choice 0 4 Step3 Select 4 in the BootWare operation Ethernet interface submenu The system prompts you to modify the network parameters ETHERNET PARAMETER SET Note...

Страница 80: ......

Страница 81: ...BootWare 4 Modify Serial Interface Parameter 0 Exit To Main Menu Enter your choice 0 4 Step3 Select 4 in the BootWare operation serial interface submenu The system prompts you to modify the baud rate...

Страница 82: ...nu Enter your choice 0 4 Step6 Select 1 in the BootWare operation serial interface submenu The following prompt appears Please Start To Transfer File Press Ctrl C To Exit Waiting CCCCCCCCCCCCCCCCCCCCC...

Страница 83: ...your access controller check the current BootWare version and application program version to make sure that the correct file is used for the upgrade After you download files with a changed baud rate t...

Страница 84: ...interface submenu For more information about this submenu see Ethernet interface submenu Configuring Ethernet interface parameters Before upgrading an application program through an Ethernet interface...

Страница 85: ...77 Upgrading applications through the management Ethernet interface The Trivial File Transfer Protocol TFTP is a TCP IP pr...

Страница 86: ...rmation about the application file types see Application files Maintaining application and configuration files You can use the file control submenu to modify and display file types Select 4 in the Boo...

Страница 87: ...ile type Step1 Select 2 in the file control submenu The following information appears M MAIN B BACKUP S SECURE N A NOT ASSIGNED NO Size B Time Type Name 1 39709988 Jul 30 2010 06 00 54 M cfa0 wx6103 b...

Страница 88: ...on password simple 123456 The output shows that password authentication is used for console port login the password is set to 123456 and it is stored in plain text IMPORTANT After reboot the system ru...

Страница 89: ......

Страница 90: ...management bracket 44 Introduction 63 M Main control boards 6 Maintaining application and configuration files 78 Mounting the access controller chassis 20 P Power supply 2 Powering on the access contr...

Отзывы: