background image

 

2-13 

Starting the device 

The following procedure uses the WX1804H-PWR access controller as an example. 

To start the device: 

1. 

Power on the device. The device initializes its memory and runs the BootWare image. The 
following information appears on the terminal screen: 

System is starting... 

Press Ctrl+D to access BASIC-BOOTWARE MENU... 

Booting Normal Extended BootWare 

Press Ctrl+T to start heavy memory test 

 

**************************************************************************** 

*                                                                          * 

*                   H3C WX1804H-PWR BootWare, Version 1.06                 * 

*                                                                          * 

**************************************************************************** 

Copyright (c) 2004-2020 New H3C Technologies Co., Ltd. 

 

Compiled Date       : Mar 10 2018 

CPU Type            : 1000MHz Multi-core Processor 

Memory Type         : DDR3 SDRAM 

Memory Size         : 1024MB 

Memory Speed        : 1333MHz 

BootWare Size       : 768KB 

Flash Size          : 1024MB 

CPLD Version        : 002 

PCB Version         : Ver.A 

 

 

BootWare Validating... 

Press Ctrl+B to access EXTENDED-BOOTWARE MENU... 

2. 

Press 

Ctrl

 + 

B

 at the prompt within 4 seconds to access the BootWare menu. 

To access the BootWare menu after the system enters the system image file reading and 
self-compressing process, restart the device. 

Loading the main image files... 

Loading file flash:/system.bin.............................................. 

......Done. 

Loading file flash:/boot.bin.........Done. 

Image file flash:/boot.bin is self-decompressing............................ 

...........................Done. 

System image is starting... 

…………

 

Line con0 is available. 

 

 

Press ENTER to get started. 

Содержание WX1804H-PWR

Страница 1: ...e 2 5 Optional Installing network port lightning protectors 2 8 Optional Installing a surge protected power strip 2 9 Connecting interface cables 2 9 Connecting the console cable and setting terminal...

Страница 2: ...open the chassis contact H3C for permission Otherwise H3C shall not be liable for any consequence Installation prerequisites You have read Preparing for installation carefully All requirements in Prep...

Страница 3: ...art for the WX1810H PWR WX1840H access controller Mounting the device on a workbench CAUTION To avoid damaging the device and affecting heat dissipation do not place heavy objects on the device Make s...

Страница 4: ...d firmly on the workbench Figure2 3 Mounting the device on a workbench Mounting the device in a 19 inch rack IMPORTANT As a best practice reserve a clearance of 1U 44 45 mm 1 75 in between adjacent de...

Страница 5: ...ets to the device 4 Supporting the bottom of the device with one hand and holding the front of the device with the other put the device in the rack Use M6 rack screws and cage nuts to attach the mount...

Страница 6: ...g cable to a length as required by the connection distance 2 Use a wire stripper to strip 5 mm 0 20 in of insulation off the end of the grounding cable 3 Slide the heat shrink tubing onto the cable an...

Страница 7: ...e rack CAUTION To ground the device by using a grounding point on the rack make sure the rack is reliably grounded The WX1810H PWR and WX1840H access controllers support grounding by using a grounding...

Страница 8: ...onductor buried in the earth The following uses the WX1840H access controller as an example If earth is available at the installation site hammer a 0 5 m 1 64 ft or longer angle iron or steel tube int...

Страница 9: ...WX1800H series access controllers The following procedure uses the WX1840H access controller as an example To install a network port lightning protector for a network port 1 Use a double faced adhesiv...

Страница 10: ...with the device Purchase one yourself if required To use a surge protected power strip first connect the AC power line routed from outdoors to the strip and then connect the power cord from the devic...

Страница 11: ...em from contamination and ESD damage Never bend an optical fiber excessively The bend radius of an optical fiber must be not less than 100 mm 3 94 in Keep the fiber end clean Make sure the Tx and Rx p...

Страница 12: ...WR WX1820H access controller If you use the local power source for the WX1804H PWR WX1820H access controller use a power adapter to connect the device to the power source To connect the power adapter...

Страница 13: ...e Appendix A Chassis views and technical specifications Figure2 14 Connecting the AC power cord for the WX1810H PWR access controller Verifying the installation Verify the following items before you p...

Страница 14: ...iled Date Mar 10 2018 CPU Type 1000MHz Multi core Processor Memory Type DDR3 SDRAM Memory Size 1024MB Memory Speed 1333MHz BootWare Size 768KB Flash Size 1024MB CPLD Version 002 PCB Version Ver A Boot...

Страница 15: ...2 14 3 Press Enter at the prompt and you can configure the device when the prompt H3C appears NOTE The CPLD version is automatically upgraded during the start up process...

Отзывы: