H3C WX1804H-PWR Скачать руководство пользователя страница 11

 

2-10 

The following are the required terminal settings: 

 

Bits per second

—9600. 

 Data 

bits

—8. 

 Stop 

bits

—1. 

 Parity

—None. 

 Flow 

control

—None. 

Connecting Ethernet cables 

Connecting an Ethernet copper port 

1. 

Connect one end of the Ethernet cable to an Ethernet copper port on the device, and the other 
end to an Ethernet port on the peer device. 

2. 

After powering on the device, examine the LEDs for the Ethernet copper port. 

For information about the LED description, see "Appendix B LEDs." 

Connecting a fiber port 

 

WARNING! 

Disconnected optical fibers or connectors might emit invisible laser light. Do not stare into beams or 
view directly with optical instruments when the switch is operating. 

 

 

CAUTION: 

  To connect a fiber port by using an optical fiber, first install a transceiver module in the port and 

then connect the optical fiber to the transceiver module. 

  Insert a dust cap into any open optical fiber connector and a dust plug into any open fiber port or 

transceiver module port to protect them from contamination and ESD damage. 

  Never bend an optical fiber excessively. The bend radius of an optical fiber must be not less than 

100 mm (3.94 in). 

  Keep the fiber end clean. 

  Make sure the Tx and Rx ports on a transceiver module are connected to the Rx and Tx ports on 

the peer end, respectively. 

 

Only the WX1840H access controller provides fiber ports. 

No transceiver modules are provided with the device. Purchase transceiver modules yourself as 
required. For transceiver module specifications, see "Appendix A Chassis views and technical 
specifications." 

The fiber ports on the device support only LC connectors. 

To connect an optical fiber for a fiber port: 

1. 

Remove the dust plug from the fiber port. 

2. 

Pivot the bail latch of the transceiver module up so that it catches a knob on the top of the 
transceiver module. 

3. 

Holding both sides of the transceiver module, insert the transceiver module slowly into the port. 

4. 

Identify the Rx and Tx ports on the transceiver module. Use the optical fiber to connect the Rx 
port and Tx port on the transceiver module to the Tx port and Rx port on the peer end, 
respectively. 

5. 

Examine the port LEDs: 

{

 

If the LED is on, a fiber link has been set up. 

Содержание WX1804H-PWR

Страница 1: ...e 2 5 Optional Installing network port lightning protectors 2 8 Optional Installing a surge protected power strip 2 9 Connecting interface cables 2 9 Connecting the console cable and setting terminal...

Страница 2: ...open the chassis contact H3C for permission Otherwise H3C shall not be liable for any consequence Installation prerequisites You have read Preparing for installation carefully All requirements in Prep...

Страница 3: ...art for the WX1810H PWR WX1840H access controller Mounting the device on a workbench CAUTION To avoid damaging the device and affecting heat dissipation do not place heavy objects on the device Make s...

Страница 4: ...d firmly on the workbench Figure2 3 Mounting the device on a workbench Mounting the device in a 19 inch rack IMPORTANT As a best practice reserve a clearance of 1U 44 45 mm 1 75 in between adjacent de...

Страница 5: ...ets to the device 4 Supporting the bottom of the device with one hand and holding the front of the device with the other put the device in the rack Use M6 rack screws and cage nuts to attach the mount...

Страница 6: ...g cable to a length as required by the connection distance 2 Use a wire stripper to strip 5 mm 0 20 in of insulation off the end of the grounding cable 3 Slide the heat shrink tubing onto the cable an...

Страница 7: ...e rack CAUTION To ground the device by using a grounding point on the rack make sure the rack is reliably grounded The WX1810H PWR and WX1840H access controllers support grounding by using a grounding...

Страница 8: ...onductor buried in the earth The following uses the WX1840H access controller as an example If earth is available at the installation site hammer a 0 5 m 1 64 ft or longer angle iron or steel tube int...

Страница 9: ...WX1800H series access controllers The following procedure uses the WX1840H access controller as an example To install a network port lightning protector for a network port 1 Use a double faced adhesiv...

Страница 10: ...with the device Purchase one yourself if required To use a surge protected power strip first connect the AC power line routed from outdoors to the strip and then connect the power cord from the devic...

Страница 11: ...em from contamination and ESD damage Never bend an optical fiber excessively The bend radius of an optical fiber must be not less than 100 mm 3 94 in Keep the fiber end clean Make sure the Tx and Rx p...

Страница 12: ...WR WX1820H access controller If you use the local power source for the WX1804H PWR WX1820H access controller use a power adapter to connect the device to the power source To connect the power adapter...

Страница 13: ...e Appendix A Chassis views and technical specifications Figure2 14 Connecting the AC power cord for the WX1810H PWR access controller Verifying the installation Verify the following items before you p...

Страница 14: ...iled Date Mar 10 2018 CPU Type 1000MHz Multi core Processor Memory Type DDR3 SDRAM Memory Size 1024MB Memory Speed 1333MHz BootWare Size 768KB Flash Size 1024MB CPLD Version 002 PCB Version Ver A Boot...

Страница 15: ...2 14 3 Press Enter at the prompt and you can configure the device when the prompt H3C appears NOTE The CPLD version is automatically upgraded during the start up process...

Отзывы: