![H3C WX Series Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/h3c/wx-series/wx-series_getting-started-manual_3059533026.webp)
26
The WX3008 supports 4-port PoE+ with the maximum output power of 25 W per port, provides a
maximum of 125 W internal power supply, supports PoE+ for 4 ports simultaneously, supports
PoE (802.3af) on four ports, and supports PoE for four ports simultaneously.
The WX6103 access controller switch interface board
cannot be started
Symptom
The WX6103 access controller switch interface board cannot be started, and you
cannot enter the user prompt.
Solution
Check that:
1.
The switch interface board is well inserted into the chassis.
2.
If the LEDs of the switch interface board are all off, the switch interface board may
not be powered on. If the LEDs are all on, the switch interface board may be faulty
or is not well inserted into the chassis. Re-insert the switch interface board in the
latter case.
3.
The hardware components on the switch interface board are normal. For example,
check whether the heat sink components are properly connected or fall off. In
case of a falloff, re-install the component with the specific material.
4.
If the problem still exists, contact the service engineer.
The main control board on the WX6103 access
controller cannot be started
Symptom
The WX6103 access controller main control board cannot be started, and you cannot
enter the user prompt.