6
firmware is being upgraded from the OM.
•
Off
—The UID LED is not activated.
2
RUN LED (RUN)
•
Steady green/off
—A system failure has occurred.
•
Flashing green (4 Hz)
—The system is being loaded.
•
Flashing green (1 Hz)
—The system is operating correctly.
3
Health LED (
)
•
Steady green
—The switch module is operating correctly.
•
Flashing red (
1 Hz
)
—An alarm is present on the switch module.
•
Off
—No power is present on the switch module, or the switch
module is not installed securely in the slot.
4
25-GE fiber port
LED
•
Steady green
—A link is present on the port and the port rate is 25
Gbps, but no data is being transmitted or received on the port.
•
Flashing green
—A link is present on the port and the port rate is 25
Gbps, and data is being transmitted or received on the port.
•
Steady yellow
—A link is present on the port and the port rate is 10
Gbps, but no data is being transmitted or received on the port..
•
Flashing yellow
—A link is present on the port and the port rate is
10 Gbps, and data is being transmitted or received on the port.
•
Off
—No link is present on the port.
5
100-GE fiber
port/breakout
interface LED
Not spitted
The LED nearest to the port indicates the port status. The
other three LEDs are off.
•
Steady green
—A link is present on the port and the
port rate is 100 Gbps, but no data is being transmitted
or received on the port.
•
Flashing green
—A link is present on the port and the
port rate is 100 Gbps, and data is being transmitted or
received on the port.
•
Steady yellow
—A link is present on the port and the
port rate is 40 Gbps, but no data is being transmitted
or received on the port.
•
Flashing yellow
—A link is present on the port and
the port rate is 40 Gbps, and data is being transmitted
or received on the port.
•
Off
—No link is present on the port.
Split into 4
× 25-GE
ports
Each of the four LEDs indicates the operating status of a
breakout interface:
•
Steady green
—A link is present on the breakout
interface and the interface rate is 25 Gbps, but no data
is being transmitted or received on the interface.
•
Flashing green
—A link is present on the breakout
interface and the interface rate is 25 Gbps, and data is
being transmitted or received on the interface.
•
Off
—No link is present on the interface
Split into 4
× 10GE
ports
Each of the four LEDs indicates the operating status of a
breakout interface:
•
Steady green
—A link is present on the breakout
interface and the interface rate is 10 Gbps, but no data
is being transmitted or received on the interface.
•
Flashing green
—A link is present on the breakout
interface and the interface rate is 10 Gbps, and data is
being transmitted or received on the interface.
•
Off
—No link is present on the interface
•
For the location and appearance of the LEDs, see
•
For information about splitting a 100-GE fiber port and combining breakout interfaces, see "Splitting a
100-GE interface and combining breakout interfaces into a 100-GE interface."