47
Front panel
Figure 34
Front panel
(1) SFP port
(2) System status LED (RUN)
(3) SFP status LED
(4) Ejector lever
(5) Captive screw
Specifications
Table 52
Specifications
Item Specification
Flash 4
MB
Memory type and size
•
DDR2 SDRAM
•
2 GB (default, two 1 GB memory modules)
CAUTION:
Use two DDR2 SDRAM modules of the same size at a time.
NVRAM 128
KB
Max power consumption
•
Tested
—132 W
•
Theoretical
—200 W
NOTE:
The theoretical max power consumption, greater than the tested max power consumption, is the upper
power consumption threshold defined for the SAP to prevent power module overloading. You must use the
theoretical max power consumption, rather than the tested max power consumption, to calculate the total
power consumption for managing power modules and determining power module numbers.
LEDs
Table 53
LED description
LED Status Description
RUN
(Green)
Off
No power input is available or the SAP-48GBP has failed.
Slow flashing (1 Hz) The SAP-48GBP is operating correctly.
Fast flashing (8 Hz)
System software image is being loaded (in this case, never power
off the device or hot-swap the SAP-48GBP; otherwise, the
SAP-48GBP might be damaged).
SFP 0 to SFP 47
(Yellow/green)
Off
No link is present or the cable is faulty.
Steady green
A 1000 Mbps link is present