35
Interface information not displayed
Symptom
An interface module is installed on the device, but no information about its interfaces is displayed in
the
display interface brief
command output.
Solution
To resolve the problem:
1.
Execute the
display device verbose
command to identify the interface module type and state.
2.
See the interface module manual to determine whether the LPU supports the interface module.
3.
If the problem persists, execute the
display hardware internal util slot slot-num
nvlog
start
num
command to collect log messages and contact H3C Support.
Interface module information not displayed
Symptom
An interface module is installed on the device, but no information about the interface module is
displayed in the
display device verbose
command output.
Solution
To resolve the problem:
1.
See the interface module manual to determine whether the LPU supports the interface module.
2.
Execute the
display hardware internal pci device slot slot-num
command in probe view.
For example, if the interface module is installed in slot 5, execute the command as follows:
[System-probe]display hardware internal pci device slot 5
… … … …
<02:05.00> pex8624 unit 1 port 5
<09:00.00> tsi384 linking subslot 2
<10:00.00> pci device in subslot 2
<02:06.00> pex8624 unit 1 port 6
<14:00.00> fpga for subslot 2
… … … …
If the command output does not contain the
pci device in subslot x
message, contact H3C
Support.
If the command output contains the message, go to step
3.
Locate the
pci device in subslot
x
message in the command output and copy the text in the
square brackets (<>) on the left of the message. Then execute the
display hardware internal
pci config
x
slot
y
command, where
x
represents the copied text and
y
represents the interface
module slot number.
Use the command output in step
.
The copied text is
10:00.00
.
[System-probe]display hardware internal pci config 10:00.00 slot 5
<04:00.00> configuration space:
0000: dc 18 01 48 06 00 a0 02 12 00 80 02 00 ff 00 00