32
Displaying the operational status of power
supplies
Use the
display power
command to display the operational status of power supplies.
<Sysname> display power
Slot 1 Power 0 Status: Normal
Slot 1 Power 1 Status: Absent
Table 13 Output description
Field
Description
Power
Number of the power supply.
Status
Power supply state:
•
Normal
—The power supply is operating correctly.
•
Absent
—The power supply is not present.
•
Abnormal
—The power supply has failed.
Displaying temperature information for the device
Use the
display environment
command to display the temperature information for the device.
<Sysname> display environment
System Temperature information (degree centigrade):
--------------------------------------------------------------------------------
---------
Slot Sensor Temperature LowerLimit Warning-UpperLimit Alarm-UpperLimit
Shutdown-UpperLimit
1 inflow 1 36 0 60 70
NA
1 inflow 2 34 0 60 70
NA
1 outflow 1 42 0 60 70
NA
1 hotspot 1 62 0 80 92
NA
Table 14 Output description
Field
Description
Slot
Slot number of the interface module.
Sensor
Temperature sensor:
•
inflow
—Air inlet vent temperature sensor.
•
outflow
—Air outlet vent temperature sensor.
Temperature
Current temperature.
LowerLimit
Low temperature alarm threshold.
Warning-UpperLimit
High temperature warning threshold.
Alarm-UpperLimit
High temperature alarm threshold.