26
Digital Diagnostic Monitoring : YES
Vendor Name : H3C
2.
Perform either of the following tasks:
{
If the vendor name field does not display H3C, replace the transceiver module with an H3C
transceiver module.
{
If the vendor name field displays H3C, execute the
display hardware internal
transceiver register interface
command in probe view. Provide the transceiver
module information to H3C Support to verify that the transceiver module is an H3C
transceiver module. If it is not an H3C transceiver module, replace it with an H3C
transceiver module.
<Sysname> system-view
[Sysname] probe
[Sysname-probe] display hardware internal transceiver register interface
Ten-GigabitEthernet1/0/1 device a0 address 0 le 128
Ten-GigabitEthernet1/0/1 transceiver device a0 register information:
0000: 03 04 07 00 00 00 02 00
0008: 00 00 00 03 0d 00 64 00
0010: 00 00 00 00 48 69 73 65
0018: 6e 73 65 20 20 20 20 20
0020: 20 20 20 20 00 00 00 00
0028: 4c 54 44 31 35 33 31 2d
0030: 42 43 2b 2d 48 33 43 20
0038: 57 20 20 20 06 0e 00 d4
0040: 00 1a 14 14 5a 57 35 30
0048: 39 43 30 30 30 30 38 20
0050: 20 20 20 20 30 39 31 32
0058: 30 31 20 20 68 b0 01 f2
0060: 48 33 43 00 00 00 00 00
0068: 00 00 00 00 00 00 00 00
0070: 00 00 00 00 00 06 0e 05
0078: 00 00 00 9e 00 89 00 fe
3.
If the issue persists, contact H3C Support.
Transceiver module does not support digital
diagnosis
Symptom
The output from the
display transceiver diagnosis interface
command shows that the
transceiver module does not support the digital diagnosis function.
<Sysname> display transceiver diagnosis interface ten-gigabitethernet 1/0/1
The transceiver does not support this function.