223
Device management commands
clock datetime
Use
clock datetime
to set the UTC time.
Syntax
clock datetime
time date
Default
The UTC time is the factory-default time.
Views
User view
Predefined user roles
network-admin
Parameters
time
: Specifies a time in the
hh:mm:ss
format. The value range for
hh
is 0 to 23. The value range for
mm
is 0 to 59. The value range for
ss
is 0 to 59. The leading zero in a segment can be omitted. If the
seconds segment is 0 (
hh
:
mm
:00), you can omit it. If both the minutes and seconds segments are 0
(
hh
:00:00), you can omit both of the segments. For example, to specify 08:00:00, you can enter 8.
date
: Specifies a date in the
MM/DD/YYYY
or
YYYY/MM/DD
format. The
value range for
YYYY
is
2000 to 2035. The value range for
MM
is 1 to 12. The value range for
DD
varies by month.
Usage guidelines
When the system time source is the local system time, the system time varies by the following items:
•
Local time zone.
•
UTC time.
•
Daylight saving time.
To view the system time, use the
display clock
command.
The correct system time setting is essential to network management and communication. To run a
device on a network, you must perform one of the following tasks on the device:
•
Set the system time correctly.
•
Use NTP or PTP to synchronize the device with a trusted time source.
Examples
# Set the UTC time to 08:08:08 01/01/2012.
<Sysname> clock datetime 8:8:8 1/1/2012
# Set the UTC time to 08:10:00 01/01/2012.
<Sysname> clock datetime 8:10 2012/1/1