H3C s5820x series Скачать руководство пользователя страница 16

display switchover state 

Use 

display

 

switchover

 

state

 to display the master/subordinate switchover states of IRF member switches. 

Syntax 

display switchover state 

slot 

member-id

 

] [ 

|

 { 

begin

 | 

exclude

 | 

include

 } 

regular-expression

 ] 

Views 

Any view 

Default command level 

1: Monitor level 

Parameters 

slot 

member-id

: Specifies an IRF member by its member ID. If no IRF member is specified, this command 

displays the master/subordinate switchover states of the master. 

|

: Filters command output by specifying a regular expression. For more information about regular 

expressions, see 

Fundamentals Configuration Guide

begin

: Displays the first line that matches the specified regular expression and all lines that follow. 

exclude

: Displays all lines that do not match the specified regular expression. 

include

: Displays all lines that match the specified regular expression. 

regular-expression

: Specifies a regular expression, a case-sensitive string of 1 to 256 characters. 

Examples 

# Display the master/subordinate switchover states of the master. 

<Sysname> display switchover state 

Master HA State to slot 2: Slave is absent. 

Master HA State to slot 3: Realtime backup to slave. 

Master HA State to slot 4: Waiting batch backup request from slave. 

Table 6

 

Command output for the master 

Field Description 

Master HA State to slot 

slot-number

 

Describes the master/subordinate switchover state 
between the master and a specific member. The 

slot-number

 argument represents an IRF member ID.  

Slave is absent 

The IRF member ID is not used in this IRF fabric.  

Waiting batch backup request from slave 

The master switch is waiting for the batch backup 
request from the subordinate switch. 

Batch backup 

The subordinate switch is bulk-backing up data from 
the master. 

Realtime backup to slave 

The subordinate switch is backing up real-time data 
from the master switch. 

Data smooth 

The subordinate switch is transitioning to be the 
master.  

 

# Display the master/subordinate switchover state of member switch 3. 

<Sysname> display switchover state slot 3 

Содержание s5820x series

Страница 1: ...H3C S5820X S5800 Switch Series IRF Command Reference Hangzhou H3C Technologies Co Ltd http www h3c com Software version Release 1805P02 Release 1808P12 Document version 6W101 20140314...

Страница 2: ...gine SecPath SecCenter SecBlade Comware ITCMM and HUASAN are trademarks of Hangzhou H3C Technologies Co Ltd All other trademarks that may be mentioned in this manual are the property of their respecti...

Страница 3: ...n feedback Audience This documentation is intended for Network planners Field technical support and servicing engineers Network administrators working with the S5820X S5800 series Added and modified c...

Страница 4: ...e choice multiple choices or none 1 n The argument or keyword and argument combination before the ampersand sign can be entered 1 to n times A line that starts with a pound sign is comments GUI conven...

Страница 5: ...es and technologies Pluggable module description PSR150 A PSR150 D Series Power Modules User Manual Describes the appearances features specifications installation and removal of the pluggable 150W pow...

Страница 6: ...R switches in different cases RPS Ordering Information for H3C Low End Ethernet Switches Provides the RPS and switch compatibility matrix and RPS cable specifications Hardware installation S5800 Serie...

Страница 7: ...information and software upgrading Obtaining documentation You can access the most up to date H3C product documentation on the World Wide Web at http www h3c com Click the links on the top navigation...

Страница 8: ...auto update enable 9 irf domain 10 irf link delay 10 irf mac address persistent 11 irf member description 12 irf member priority 12 irf member renumber 13 irf switch to 15 irf port 15 irf port load sh...

Страница 9: ...first line that matches the specified regular expression and all lines that follow exclude Displays all lines that do not match the specified regular expression include Displays all lines that match...

Страница 10: ...utomatically propagates its system software image to the switch you are adding to the IRF fabric no Disabled You must manually make sure the joining switch uses the same system software image as the m...

Страница 11: ...or ports bound to IRF port 1 If no physical ports are bound to the IRF port this field displays disable IRF Port2 Physical port or ports bound to IRF port 2 If no physical ports are bound to the IRF...

Страница 12: ...o device is connected to the IRF port this field displays two hyphens Belong To IRF fabric that has the switch represented by the CPU MAC address of the master in the IRF fabric display irf port load...

Страница 13: ...based sharing Layer 3 traffic packet type based sharing Display the global IRF link load sharing mode In this example because a global sharing mode based on source and destination IP addresses have b...

Страница 14: ...link load sharing criteria In this sample output the criteria are source and destination MAC addresses Information displayed in this field depends on user configuration display mad Use display mad to...

Страница 15: ...orts and ports that are configured to not shut down Detect to Recovery State of the IRF fabric is transitioning from Detect to Recovery for example as the result of an IRF split Recovery to Detect Sta...

Страница 16: ...a case sensitive string of 1 to 256 characters Examples Display the master subordinate switchover states of the master Sysname display switchover state Master HA State to slot 2 Slave is absent Master...

Страница 17: ...inate switches is enabled Views System view Default command level 3 Manage level Usage guidelines When you add a switch to the IRF fabric the software auto update function compares the system software...

Страница 18: ...event IRF fabrics from interfering with one another If one IRF fabric uses another IRF fabric as the intermediate device for ARP MAD or LACP MAD you must assign the two IRF fabrics different domain ID...

Страница 19: ...ac address persistent to enable the IRF fabric to change its bridge MAC address as soon as the master leaves Syntax irf mac address persistent always timer undo irf mac address persistent Default Afte...

Страница 20: ...le IRF bridge MAC persistence Examples Enable the IRF bridge MAC address to persist forever Sysname system view Sysname irf mac address persistent always irf member description Use irf member descript...

Страница 21: ...ric information Sysname display irf Switch Role Priority CPU Mac 1 Slave 29 00e0 fc00 1115 2 Slave 1 00e0 fc00 1615 3 Master 32 00e0 fc00 1015 9 Slave 30 00e0 fc00 1515 indicates the device is the mas...

Страница 22: ...nging member IDs after the IRF fabric is formed The new member ID takes effect at a reboot After the switch reboots the settings on all member ID related physical resources including common physical n...

Страница 23: ...o execute a limited set of maintenance commands At the CLI of a subordinate switch you are placed in user view and the command prompt changes to Sysname Slave member ID slot number for example Sysname...

Страница 24: ...name Ten GigabitEthernet3 0 25 shutdown Sysname Ten GigabitEthernet3 0 25 quit Sysname irf port 3 1 Sysname irf port 3 1 port group interface ten gigabitethernet 3 0 25 Sysname irf port 3 1 quit Sysna...

Страница 25: ...lies Examples Configure the global IRF link load sharing mode to distribute traffic based on destination MAC address Sysname system view Sysname irf port load sharing mode destination mac Configure IR...

Страница 26: ...GigabitEthernet1 0 27 quit Sysname irf port 1 2 Sysname irf port1 2 port group interface Ten GigabitEthernet 1 0 27 Sysname irf port1 2 quit Sysname interface ten gigabitEthernet 1 0 27 Sysname Ten G...

Страница 27: ...ng tree feature between the IRF fabric and the intermediate device Enable the IRF fabric to change its bridge MAC address as soon as the master leaves Create the ARP MAD VLAN and assign the ports on t...

Страница 28: ...spanning tree feature on any Layer 2 Ethernet ports in the BFD MAD VLAN The MAD function is mutually exclusive with the spanning tree feature Do not bind a BFD MAD enabled VLAN interface to any VPN i...

Страница 29: ...CP MAD on Bridge Aggregation 1 a Layer 2 dynamic aggregate interface Sysname system view Sysname interface bridge aggregation 1 Sysname Bridge Aggregation1 mad enable Enable LACP MAD on Route Aggregat...

Страница 30: ...itEthernet 2 0 5 from being shut down when the MAD status transitions to Recovery Sysname system view Sysname mad exclude interface gigabitethernet 2 0 5 mad ip address Use mad ip address to assign a...

Страница 31: ...3 Sysname Vlan interface3 mad ip address 192 168 0 1 255 255 255 0 member 1 Assign a MAD IP address to IRF member 2 on VLAN interface 3 Sysname Vlan interface3 mad ip address 192 168 0 2 255 255 255 0...

Страница 32: ...rate in enhanced mode To support MPLS L2VPN or VPLS use the enhanced mode normal Sets the physical IRF port to operate in normal mode Usage guidelines Before binding a physical port to an IRF port or...

Страница 33: ...25 Sysname irf port3 1 quit Sysname interface ten gigabitethernet 3 0 25 Sysname Ten GigabitEthernet3 0 25 undo shutdown...

Страница 34: ...ate enable 9 irf domain 10 irf link delay 10 irf mac address persistent 1 1 irf member description 12 irf member priority 12 irf member renumber 13 irf switch to 15 irf port 15 irf port load sharing m...

Отзывы: