8-2
z
If the probe fails, the status of the corresponding Track object is
Negative
.
If the probe result is invalid (for example, the NQA test group collaborating with the track entry does
not exist.), the status of the track entry is
Invalid
.
At present, the detection modules that can collaborate with the Track module is the Network Quality
Analyzer (NQA). Refer to
NQA Configuration
in the
Network Management and Monitoring Command
Reference
for details of NQA.
Collaboration Between the Track Module and the Application Modules
You can establish the collaboration between the Track module and the application modules through
configuration. If the status of the Track object changes, the Track module tells the application modules
to deal with the change accordingly.
At present, the application modules that can collaborate with the Track module is Static routing
Track Configuration Task List
To implement the collaboration function, establish collaboration between the Track module and the
detection modules, and between the Track module and the application modules.
Complete these tasks to configure Track module:
Task
Remarks
Configuring Collaboration Between the Track
Module and the Detection Modules
Required
Configuring Collaboration Between the Track
Module and the Application Modules
Required
Configuring Collaboration Between the Track Module and the
Detection Modules
Configuring Track-NQA Collaboration
Through the following configuration, you can establish the collaboration between the Track module
and the NQA, which probes the link status and informs the Track module of the probe result.
Follow these steps to configure Track-NQA collaboration:
To do…
Use the command…
Remarks
Enter system view
system-view
—