5
NOTE:
Only the S5500-28SC-HI and S5500-52SC-HI need a fan tray.
Installing the switch in a 19-inch rack
You can install an S5500-HI switch in a 19-inch rack by using one of the following methods:
•
Use the front mounting brackets.
Figure 2
shows the mounting procedure diagram.
•
Use the front and rear mounting brackets.
Figure 3
shows the mounting procedure diagram.
•
Use the front mounting brackets and mounting rail assemblies.
Figure 4
shows the mounting
procedure diagram.
NOTE:
If a rack shelf is available, you can put the switch on the rack shelf, slide the switch to an appropriate
position, and attach the switch to the rack with mounting brackets.
Figure 2
Rack-mounting procedure (1)
Figure 3
Rack-mounting procedure (2)
Figure 4
Rack-mounting procedure (3)
Rack-mounting restrictions and guidelines
Follow the rack-mounting restrictions and guidelines in
Table 3
, depending on the mounting accessories
that you use.
Attach the
chassis rails to
the two sides of
the chassis
Connect the two-
hole lug grounding
cable to the side
grounding point
Attach the
slide rails to
the rack
Install the front
mounting brackets in
the mounting position
near the power modules
Mount the
chassis in the
rack
Attach the
chassis rails to
the two sides of
the chassis
Attach the
slide rails to
the rack
Install the front
mounting brackets in
the mounting position
near the power modules
Mount the
chassis in the
rack
Connect the one-
hole lug grounding
cable to the rear
grounding point
(Approach 1) Use side grounding point:
(Approach 2) Use rear grounding point: