Troubleshooting flowchart
Figure 16 Troubleshooting error frames (for example, CRC errors) on a port
Solution
To resolve the issue:
1.
(Optional.) Use the
reset counter interface
command in user view to clear the packet statistics
of the port.
This command resets the values of each statistical field to 0, so that you can view the statistics
changes more clearly.
2.
If the port is a fiber port, verify that the optical power of the transceiver module is operating
correctly:
a.
Use the
display transceiver diagnosis interface
command in probe view to view the
present measured values of the digital diagnosis parameters for the transceiver module.
b.
If the optical power of the transceiver module is not within the correct range, replace the
transceiver module with a transceiver module of the same model that is operating correctly.
[Sysname-probe] display transceiver diagnosis interface ten-gigabitethernet 1/0/1
Replace it with a transceiver
module with correct optical
power
Optical power
of transceiver
module correct?
Determine the type of error
frames accumulating
Yes
Configure matching speed
and duplex
No
No
Yes
Use correct port and link
medium
No
Yes
No
No
No
View the number of
received flow control frames
Yes
Yes
Yes
Contact the support
End
Error frames on the port
Resolved?
Speed and
duplex match the
peer port?
Port and link
medium correct?
Resolved?
Resolved?
No