![H3C MSR3610-X1 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/h3c/msr3610-x1/msr3610-x1_installation-manual_574900022.webp)
15
Figure 14 Grounding the device with a grounding strip
Grounding the device by burying a grounding conductor in
the earth ground
If the installation site does not have any grounding strips, but earth ground is available, hammer a 0.5
m (1.64 ft) or longer angle iron or steel tube into the earth ground to serve as a grounding conductor.
The steel tube must be zinc-coated. Weld the yellow-green grounding cable to the angel iron or steel
tube and treat the joint for corrosion protection.
Installing interface modules
Installing a SIC
CAUTION:
SICs are not hot swappable. Make sure the device is powered off before installing a SIC.
To install a SIC:
1.
Use a Phillips screwdriver to remove the fastening screws on the filler panel and remove the
filler panel. See
2.
Push the SIC slowly into the slot along the guide rails until it makes close contact with the
backplane of the device. See
3.
Fasten the captive screws on the SIC.
Содержание MSR3610-X1
Страница 33: ...26 Figure 30 Removing a transceiver module ...