Table 135 LED description
LED
Indication
STATUS
•
Steady green: The MIM-HNDE module is powered on properly.
•
Off: There is no power supply, damaged power supply, or sever hardware failure.
ACTIVE
•
Off after flashing yellow for two seconds: The MIM-HNDE module has been
initialized.
•
Flashing continuously: The MIM-HNDE module operates normally and there is
data transmission with the host.
•
Off: The MIM-HNDE module runs normally and no data transmission exists with
the host.
Troubleshooting
Symptom 1
The STATUS LED stays off after turning on the router.
Troubleshooting
The STATUS LED should stay steady on after powered on. The Off status indicates that the
MIM-HNDE module or some hardware is not powered on properly. Check the connection of the
power supply.
If the device is powered on, the failure may due to the damaged power supply of the module, or
abnormal operation of CPLD (Complex Programmable Logic Device). In these circumstances,
contact our agents for support.
Symptom 2
The ACTIVE LED stays off when powering on the router.
Troubleshooting
When powering up the device, the ACTIVE LED should flashing for two seconds before turning off,
which indicates the encryption processor of the MIM-HNDE module has been configured and is
ready for work. If the ACTIVE LED stays on when powering up the device, this means the
initialization of the processor fails and the system bus does not work normally. Check the connection
between the MIM-HNDE module and the host. If the connection is good, the abnormal status may
due to the host or the MIM-HNDE module, contact our agents for support.
Symptom 3
The ACTIVE LED stays on or off when the MIM-HNDE module is running.
Troubleshooting
The ACTIVE LED should be flashing when the MIM-HNDE module runs the encryption service. The
steady on or off indicates the system bus works abnormally. Check the connection between the
MIM-HNDE module and host. If the connection is good, the abnormal status may due to the host or
the MIM-HNDE module, contact our agents for support.