When installing the OAP card, note the following: 

z

 

Do not touch the components on the surface of the OAP card.  

z

 

Do not apply excessive force while installing the OAP card. If you cannot insert the OAP card 

smoothly, check whether the installation mode (reverse insertion) is correct.  

 

Step5 

Fasten the captive screws on the OAP card clockwise with the Philips screwdriver until the OAP card is 

fixed into the chassis. 

Remove an OAP card 

Step1 

Wear an ESD-preventive wrist strap, ensure a good skin contact and make sure that the 

ESD-preventive wrist strap is properly grounded. 

Step2 

Loosen the captive screws on the OAP card counterclockwise with the Philips screwdriver until all 

spring pressure is released. 

Step3 

Hold each ejector lever with a hand and pull the ejector levers outward (see (4) in 

 

Figure 3-5). Then pull 

out the OAP card slowly along the guide rails (see (3) in 

 

Figure 3-5).  

Figure 3-5 

Remove the OAP card 

 

(1) OAP card 

(2) Rear panel of the switch 

(3) Removal direction of the OAP card 

(4) Unlocking direction of the ejector levers 

 

 

The protection panel on the OAP card surface has a yellow warning label 

, indicating that this 

area corresponds to the inner heat radiator. After the OAP card runs for a period of time, this area may 

be very hot. So keep your hands away from the area while removing the OAP card to avoid being hurt.  

 

Содержание LSWM1FW10

Страница 1: ...H3C OAP Cards User Manual New H3C Technologies Co Ltd http www h3c com Manual Version 6PW102 20180112...

Страница 2: ...ne SecPath SecCenter SecBlade Comware ITCMM and HUASAN are trademarks of New H3C Technologies Co Ltd All other trademarks that may be mentioned in this manual are the property of their respective owne...

Страница 3: ...cause data loss or damage to equipment Means a complementary description Obtaining Documentation and Technical Support To obtain up to date documentation and technical support go to http www h3c com a...

Страница 4: ...nce 2 1 Front Panel 2 1 Appearance 2 1 Description of the LEDs 2 1 Management Ethernet Port 2 2 Hardware Specifications 2 3 3 Installing an OAP Card 3 1 Installing and Removing an OAP Card 3 1 Connect...

Страница 5: ...tack defense and P2P flow control thus effectively ensuring network security supports multiple VPN services such as IPsec VPN thus allowing you to build various VPNs supports multiple routing protocol...

Страница 6: ...ll card Appearance Figure 2 1 OAP card appearance 1 Ejector lever 2 Fastening screw captive screw 3 Front panel of the OAP card Front Panel Appearance Figure 2 2 Front panel of an OAP card 1 CF card i...

Страница 7: ...een Steady green The CF card is normal and no read write operation is performed Blinking green The CF card is normal and a read write operation is performed Off No CF card is in the slot Management Et...

Страница 8: ...AP card hardware specifications Item Specification Remarks CPU MIPS eight cores 1 GHz Memory 2 GB Avoid replacing the memory by yourself to prevent damage to the OAP card Number of CF card interfaces...

Страница 9: ...rap ensure a good skin contact and make sure that the ESD preventive wrist strap is properly grounded Step2 Loosen the captive screws on the blank panel counterclockwise with a Phillips screwdriver as...

Страница 10: ...ard Figure 3 3 Reversely insert an OAP card Step4 Push the OAP card slowly along the guide rails see 3 in Figure 3 4 and then push the ejector levers inward to lock the OAP card in position see 4 in F...

Страница 11: ...ly grounded Step2 Loosen the captive screws on the OAP card counterclockwise with the Philips screwdriver until all spring pressure is released Step3 Hold each ejector lever with a hand and pull the e...

Страница 12: ...OAP card to the Ethernet port of a PC or router use a crossover cable z To connect the management Ethernet port of an OAP card to the Ethernet port of a hub or switch use a straight through cable Ste...

Отзывы: